Experimental study of cold-formed steel built-up columns

被引:71
|
作者
Meza, Francisco J. [1 ]
Becque, Jurgen [1 ]
Hajirasouliha, Iman [1 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Built-up column; Experiment; Cold-formed steel; Stability; Buckling; Imperfection measurements; DOUBLE-Z MEMBERS; SECTION COLUMNS; DESIGN;
D O I
10.1016/j.tws.2019.106291
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A comprehensive experimental programme was contrived with the aim of investigating the behaviour and the capacity of cold-formed steel built-up columns with particular emphasis on the effects of connector spacing and contact between individual components. A total of 24 built-up columns, including four different cross-sectional geometries, were tested between pin-ended boundary conditions, while applying the load with nominal eccentricities of L/1000 or L/1500. The columns were designed to fail by interaction of cross-sectional buckling of the components, possible global-type buckling of the components between connectors and global buckling of the whole column, and all these failure modes were successfully achieved. The built-up sections were fabricated from flat plates, plain channels and lipped channels and were assembled with either bolts or self-drilling screws. The connector spacing was varied between specimens of the same cross-sectional geometry. Tensile coupons were taken from the flat portions and the corners of the sections in order to determine their material properties, while detailed measurements of the geometric imperfections of each specimen were also carried out using a specially designed measuring rig. In addition, the isolated behaviour of both the bolts and the screws used in the specimens was investigated through single lap shear tests. It was observed that the buckling patterns in the built-up specimens were affected by contact between the various components and by the spacing between the connectors. However, in the cases where global buckling of the components in between connector points was not critical, the connector spacing had a minor influence on the ultimate capacity of the columns.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Experimental study on fire resistance of cold-formed steel built-up box columns
    Yang, Jingjie
    Wang, Weiyong
    Shi, Yu
    Xu, Lei
    THIN-WALLED STRUCTURES, 2020, 147
  • [2] Experimental Study of Cold-Formed Steel Built-Up Beams
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (07)
  • [3] Experimental investigation of the sectional buckling of built-up cold-formed steel columns
    Abbasi, Mandana
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [4] Experimental investigation of built-up cold-formed steel section battened columns
    Dabaon, Mohamed
    Ellobody, Ehab
    Ramzy, Khaled
    THIN-WALLED STRUCTURES, 2015, 92 : 137 - 145
  • [5] Numerical modelling of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    THIN-WALLED STRUCTURES, 2023, 188
  • [6] Fire resistance of built-up cold-formed steel columns
    Pires, Tiago A. C.
    do Rego Silva, Jose Jeferson
    dos Santos, Marina M. L.
    Costa, Leonardo Medeiros
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177
  • [7] Design of cold-formed steel battened built-up columns
    Dar, M. Adil
    Verma, Abhishek
    Anbarasu, M.
    Pang, Sze Dai
    Dar, A. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 193
  • [8] Experimental study of the cross-sectional capacity of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    THIN-WALLED STRUCTURES, 2020, 155
  • [9] Experimental study on the composite action in sheathed and bare built-up cold-formed steel columns
    Fratamico, David C.
    Torabian, Shahabeddin
    Zhao, Xi
    Rasmussen, Kim J. R.
    Schafer, Benjamin W.
    THIN-WALLED STRUCTURES, 2018, 127 : 290 - 305
  • [10] The Evolution and Performance of Cold-Formed Steel Built-Up Battened Columns
    Jainudin, N. F.
    Jamaluddin, N.
    Jaini, Zainorizuan Mohd
    Hakim, S. J. s
    Mohamad, Noridah
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2024, 16 (05): : 444 - 453