共 50 条
Application of Net Analyte Signal Standard Addition Method (NASSAM) for Simultaneous Determination of Lead and Tin by Differential Pulse Polarography
被引:4
|作者:
Asadpour-Zeynali, Karim
[1
]
Majidi, Mir Reza
[1
]
Vallipour, Javad
[1
]
Jafari, Samira
[1
]
机构:
[1] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz 5166616471, Iran
关键词:
Net analyte signal standard addition method;
Simultaneous determination;
Differential pulse polarography;
Lead;
Tin;
SIMULTANEOUS VOLTAMMETRIC DETERMINATION;
SOLID-PHASE EXTRACTION;
SQUARES;
CHEMOMETRICS;
ALGORITHM;
NICKEL;
PLS;
D O I:
10.1002/jccs.201190037
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
Differential pulse polarography was used for simultaneous determination of Sn2+ and Pb2+. But there is a problem for simultaneous determination and it is high overlapped DPPs of mentioned cations that their determination is impossible in the presence of each other, so multivariate calibration methods as chemomatrics methods were used for this determination. There are some disadvantageous for multivariate calibration methods that can be solved by a new and simple method called net analyte signal standard addition method. This method has some advantages, such as: the use of a full voltammogram, realization in a single step, therefore it does not require calibration and prediction steps and only a few measurements are required for the determination.
引用
收藏
页码:353 / 361