Some characteristics of hydroxylapatite powder particles after plasma spraying

被引:42
作者
Pálka, V
Postrková, E
Koerten, HK
机构
[1] Slovak Acad Sci, Inst Mat & Machine Mech, Bratislava 83008, Slovakia
[2] Leiden State Univ, Electron Microscopy Lab, NL-2333 AA Leiden, Netherlands
关键词
hydroxylapatite; plasma spraying; powder particles melting;
D O I
10.1016/S0142-9612(98)00087-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have studied the particles of hydroxylapatite (HA) powder, the particles after plasma spraying, their distribution on substrate surface and their condition after transfer through the plasma torch. Mean particle size of HA powders was as follows: HA-A: 3.8 mu m, HA-B 88.2 mu m, The area of HA coating after plasma spraying, when the torch had a constant position against the substrate surface, shows two characteristic zones: the central part of coating formed mainly from deformed particles and the marginal part of coating with small non-deformed particles. These small non-deformed particles can be found in all zones of the coating and together with greater non-deformed particles and partially deformed particles will unfavourably affect the adhesive and cohesive strength of the coating and its porosity. The maximum diameter of the molten (spherical) particles in the conditions of Ar + H-2 plasma, output P = 24 kW was: D-A = 25 mu m (HA-A) and D-n = 65 mu m (HA-B). The intervals of dimensions in which most of molten particles occurred were HA-A: 0-15 mu m (98%), HA-B: 5-35 mu m (84%). From comparison of HA-A and HA-B powders it can be concluded that the transport of HA-A powder was not continuous, the amount of molten HA-A particles was considerably greater (90%) than that of HA-B powder (63%). Phase decomposition and also solubility of HA-A powder (at in vitro tests) was greater. If we consider transport of particles, their melting, splitting and spraying efficiency, the suitable size of HA powder particles for the given spraying conditions is somewhere between the size of HA-A and HA-B particles-let us say-in the interval from 20 to 60 mu m. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1763 / 1772
页数:10
相关论文
共 20 条
[1]   SURFACE MODIFICATIONS OF HYDROXYAPATITE CERAMICS IN AQUEOUS-MEDIA [J].
AMRAHBOUALI, S ;
REY, C ;
LEBUGLE, A ;
BERNACHE, D .
BIOMATERIALS, 1994, 15 (04) :269-272
[2]  
CHEN J, 1993, P 19 ANN M SOC BIOM, P90
[3]  
DEBRUIN JD, 1993, P 10 EUR C BIOM DAV, P12
[4]   CRYSTALLOGRAPHIC CHANGES IN CALCIUM PHOSPHATES DURING PLASMA-SPRAYING [J].
ELLIES, LG ;
NELSON, DGA ;
FEATHERSTONE, JDB .
BIOMATERIALS, 1992, 13 (05) :313-316
[5]   NEW OBSERVATIONS ON MIDDLE TERM HYDROXYAPATITE-COATED TITANIUM-ALLOY HIP PROSTHESES [J].
FRAYSSINET, P ;
HARDY, D ;
ROUQUET, N ;
GIAMMARA, B ;
GUILHEM, A ;
HANKER, J .
BIOMATERIALS, 1992, 13 (10) :668-674
[6]  
GROSS KA, 1991, 2ND P PLASM TECHN S, V3, P159
[7]   CHARACTERIZATION OF THERMAL SPRAYED HYDROXYAPATITE POWDERS AND COATINGS [J].
KHOR, KA ;
CHEANG, P .
JOURNAL OF THERMAL SPRAY TECHNOLOGY, 1994, 3 (01) :45-50
[8]   LONG-TERM IN-VIVO STUDY OF PLASMASPRAYED COATINGS ON TITANIUM-ALLOYS OF TETRACALCIUM PHOSPHATE, HYDROXYAPATITE AND ALPHA-TRICALCIUM PHOSPHATE [J].
KLEIN, CPAT ;
PATKA, P ;
WOLKE, JGC ;
DEBLIECKHOGERVORST, JMA ;
DEGROOT, K .
BIOMATERIALS, 1994, 15 (02) :146-150
[9]   X-RAY-DIFFRACTION STUDIES ON PLASMA-SPRAYED CALCIUM PHOSPHATE-COATED IMPLANTS [J].
KOCH, B ;
WOLKE, JGC ;
DEGROOT, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (06) :655-667
[10]  
MATEJKA D, 1991, P 2 PLASM TECHN S PL, V3, P171