Studies on neurosteroids XIV. Levels of dehydroepiandrosterone sulfate in rat brain and serum determined with newly developed enzyme-linked immunosorbent assay
被引:19
|
作者:
论文数: 引用数:
h-index:
机构:
Higashi, T
[1
]
Daifu, Y
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ, Fac Pharmaceut Sci, Kanazawa, Ishikawa 9200934, JapanKanazawa Univ, Fac Pharmaceut Sci, Kanazawa, Ishikawa 9200934, Japan
Daifu, Y
[1
]
Shimada, K
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ, Fac Pharmaceut Sci, Kanazawa, Ishikawa 9200934, JapanKanazawa Univ, Fac Pharmaceut Sci, Kanazawa, Ishikawa 9200934, Japan
Shimada, K
[1
]
机构:
[1] Kanazawa Univ, Fac Pharmaceut Sci, Kanazawa, Ishikawa 9200934, Japan
An enzyme-linked immunosorbent assay (ELISA) of dehydroepiandrosterone sulfate (DHEAS), one of the neurosteroids, has been developed for measuring its brain and serum levels in rats without deconjugation. 11 alpha -Hemiglutaryloxy-DHEAS was newly synthesized, conjugated with bovine serum albumin (BSA), and immunized to rabbits for the production of anti-DHEAS antibodies. A bridge-heterologous ELISA system employing the sequential saturation method exhibited a high sensitivity with a midpoint of 100 pg. Although the antibody significantly cross-reacted with epiandrosterone sulfate, it easily discriminated the unconjugated steroids and pregnenolone sulfate, which is reported to exist in the brain at a much higher level when compared with DHEAS. The brain homogenate or serum was treated with hexane to remove the lipophilic compounds and purified with an OASIS HLB cartridge. The DHEAS levels were then determined by ELISA. The overall recovery rate through the pretreatment was a satisfactory and constant (81.8 +/- 3.4% for brain, 89.3 +/- 3.0% for serum, mean +/- standard deviation). This ELISA afforded a satisfactory serial dilution study and recovery test. The intra- and inter-assay coefficients of variation were lower than 13%, which showed the precision of the proposed method. The applied method showed that DHEAS was not detected in some brain samples and its levels were much lower than those previously reported and than its serum levels. (C) 2001 Elsevier Science Inc. All rights reserved.
机构:
Kobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, JapanKobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, Japan
Tagawa, Noriko
Ikariko, Nao
论文数: 0引用数: 0
h-index: 0
机构:
Kobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, JapanKobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, Japan
Ikariko, Nao
Fukumura, Keiko
论文数: 0引用数: 0
h-index: 0
机构:
Kobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, JapanKobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, Japan
Fukumura, Keiko
Kobayashi, Yoshibaru
论文数: 0引用数: 0
h-index: 0
机构:
Kobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, JapanKobe Pharmaceut Univ, Dept Med Biochem, Higashinada Ku, Kobe, Hyogo 6588558, Japan
机构:
Hadhramout Univ, Coll Med, Dept Med Biochem, Mukalla 50511, YemenHadhramout Univ, Coll Med, Dept Med Biochem, Mukalla 50511, Yemen
Dahman, Lotfi S. Bin
Sumaily, Khalid M.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Coll Med, Pathol Dept, Clin Biochem Unit, Riyadh 11461, Saudi ArabiaHadhramout Univ, Coll Med, Dept Med Biochem, Mukalla 50511, Yemen
Sumaily, Khalid M.
Sabi, Essa M.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Coll Med, Pathol Dept, Clin Biochem Unit, Riyadh 11461, Saudi ArabiaHadhramout Univ, Coll Med, Dept Med Biochem, Mukalla 50511, Yemen