Enantioseparation of (±)-threo-methylphenidate in human plasma by cyclodextrin-modified sample stacking capillary electrophoresis

被引:18
|
作者
Lee, Shih-Chieh [1 ]
Wang, Chun-Chi [1 ]
Yang, Pin-Chen [2 ]
Wu, Shou-Mei [1 ,3 ]
机构
[1] Kaohsiung Med Univ, Coll Pharm, Sch Pharm, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ, Chung Ho Mem Hosp, Dept Psychiat, Kaohsiung 807, Taiwan
[3] Kaohsiung Med Univ, Ctr Excellence Environm Med, Kaohsiung 807, Taiwan
关键词
Field-amplified sample stacking; Enantioseparation; (+/-)-Threo-methylphenidate; Human plasma; Capillary electrophoresis; ATTENTION-DEFICIT/HYPERACTIVITY DISORDER; DEFICIT-HYPERACTIVITY DISORDER; METHYLPHENIDATE RITALIN; CHEMICAL-IONIZATION; THREO-METHYLPHENIDATE; MASS-SPECTROMETRY; PHARMACOKINETICS; METABOLITE; SEPARATION; ACID;
D O I
10.1016/j.chroma.2011.10.072
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The (+/-)-threo-methylphenidate ((+/-)-threo-MP) is widely used for treatment of attention-deficit hyperactivity disorder (ADHD). According to clinical evidence, (+)-threo-MP possesses higher potency than (-)-threo-MP. Due to ppb level in plasma, till now, none of the capillary electrophoresis (CE) methods have been able to provide adequate sensitivity for therapeutic (+/-)-threo-MP monitoring. In this study, a cyclodextrin-modified field-amplified sample stacking CE method (CD-FASS-CE) for enantioseparation of (+/-)-threo-MP in human plasma was established for clinical applications. Phosphate buffer (50 mM, pH 3.0) was filled into uncoated fused silica capillary (40 cm, 50 mu m ID.), followed by a water plug (0.5 psi, 10 s). Electrokinetic injection (6 kV, 200 s) was used to load samples and to enhance sensitivity. Stacking and separation were performed at 20 kV and 200 nm using phosphate buffer (50 mM, pH 3.0) containing 20 mM HP-beta-CD and 30 mM triethanolamine. Analytes were separated simultaneously by using CD-FASS-CE and had a lower detection limit of equal to the sub-ppb level. Linear calibration curves were obtained from 1 to 80 ng/mL (r=0.998). The limit of detection for both isomers was 600 pg/mL. RSD and RE of precision and accuracy in intra- and inter-day assays were below 7.89%. This method was further applied to analyze (+/-)-threo-MP in four healthy Asian volunteers and that provided some relevant information for clinical treatments. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:302 / 305
页数:4
相关论文
共 50 条
  • [41] Analysis of bioactive triterpenes from Rubus chingii by cyclodextrin-modified capillary electrophoresis
    Guo, QL
    Gao, JY
    Yang, JS
    CHROMATOGRAPHIA, 2005, 62 (3-4) : 145 - 150
  • [42] Cyclodextrin-Modified Gold Nanoparticle Capillary Electrochromatography with Online Sample Stacking for Simultaneous and Sensitive Determination of Aminobenzoic Acid Isomers
    Wenhua Sun
    Yalei Dong
    Hong Cui
    Hong Zhao
    Yujian He
    Yongsheng Ding
    Xiangjun Li
    Zhuobin Yuan
    Chromatographia, 2014, 77 : 821 - 828
  • [43] Comparative study on the enantioseparation of glutethimide using dual cyclodextrin systems and cyclodextrin modified MEKC in capillary electrophoresis
    Abushoffa, AM
    Burjanadze, N
    Blaschke, G
    Crommen, J
    Chankvetadze, B
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (1-2) : 10 - 16
  • [44] Analysis of naphthalenesulfonate compounds by cyclodextrin-mediated capillary electrophoresis with sample stacking
    Chen, HC
    Ding, WH
    JOURNAL OF CHROMATOGRAPHY A, 2003, 996 (1-2) : 205 - 212
  • [45] Chiral separation of cathinone derivatives used as recreational drugs by cyclodextrin-modified capillary electrophoresis
    Mohr, Stefan
    Pilaj, Stefan
    Schmid, Martin G.
    ELECTROPHORESIS, 2012, 33 (11) : 1624 - 1630
  • [46] Preparation of cyclodextrin-modified monolithic hybrid columns for the fast enantioseparation of hydroxy acids in capillary liquid chromatography
    Szwed, Kamila
    Ou, Junjie
    Huang, Guang
    Lin, Hui
    Liu, Zhongshan
    Wang, Hongwei
    Zou, Hanfa
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (06) : 1110 - 1117
  • [47] Determination of resin acid composition in rosin samples using cyclodextrin-modified capillary electrophoresis
    Mckeon, Louise
    Regan, Fiona
    Burns, Barry
    Leonard, Ray
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (19) : 2791 - 2796
  • [48] Development and validation of a cyclodextrin-modified capillary electrophoresis method for the enantiomeric separation of vildagliptin enantiomers
    Kazsoki, Adrienn
    Fejos, Ida
    Sohajda, Tamas
    Zhou, Wei
    Hu, Wenhui
    Szente, Lajos
    Beni, Szabolcs
    ELECTROPHORESIS, 2016, 37 (10) : 1318 - 1325
  • [49] Determination of hydroxy acids in cosmetics by chemometric experimental design and cyclodextrin-modified capillary electrophoresis
    Liu, Pei-Yu
    Lin, Yi-Hui
    Feng, Chia Hsien
    Chen, Yen-Ling
    ELECTROPHORESIS, 2012, 33 (19-20) : 3079 - 3086
  • [50] Capillary electrophoresis of tetrahydroberberine alkaloids: Chiral separation by cyclodextrin-modified micellar electrokinetic chromatography
    Koyama, Junko
    Toyokuni, Izumi
    Kino, Akari
    Tagahara, Kiyoshi
    Phytochemical Analysis, 10 (04): : 175 - 180