Evaluation of the Accuracy of Computed Tomography-Based Navigation for Femoral Stem Orientation and Leg Length Discrepancy

被引:64
作者
Kitada, Makoto [1 ]
Nakamura, Nobuo [1 ]
Iwana, Daiki [1 ]
Kakimoto, Akihiro [1 ]
Nishii, Takashi [2 ]
Sugano, Nobuhiko [2 ]
机构
[1] Kyowakai Hosp, Ctr Arthroplasty, Osaka 5640001, Japan
[2] Osaka Univ, Grad Sch Med, Dept Orthopaed Med Engn, Osaka, Japan
关键词
total hip arthroplasty; femoral stem; accuracy; leg length; CT-based navigation; TOTAL HIP-ARTHROPLASTY; REPLACEMENT; MOTION; RANGE; IMPLANTATION; DYSPLASIA; CUP;
D O I
10.1016/j.arth.2010.08.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although there is a great deal in the literature about the clinical accuracy of computed tomography (CT) based navigation systems for acetabular cup orientation and leg length discrepancy in total hip arthroplasty, there is little analysis of femoral stem orientation. Thirty total hip arthroplasties in which CT-based navigation system had been used had their anteversion, valgus angle of stem, and leg length discrepancy measured on postoperative CT data. Differences in postoperative measurements from intraoperative records were -0.6 degrees +/- 4.8 degrees (range, -11 degrees to 10 degrees) for stem anteversion, -0.2 degrees +/- 1.8 degrees (range, -4 degrees to 3 degrees) for valgus angle of stem, and 1.3 +/- 4.1 mm (range, -6 to 10 mm) for leg length. Although this system may need further improvement for stem orientation, it was helpful for intraoperative leg length adjustment.
引用
收藏
页码:674 / 679
页数:6
相关论文
共 23 条
[1]   Combined Anteversion Technique for Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Malik, Aamer ;
Dastane, Manish ;
Wan, Zhinian .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :119-127
[2]   Computed tomography-based surgical navigation for hip arthroplasty [J].
Ecker, Tiyno M. ;
Tannast, Moritz ;
Murphy, Stephen B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :100-105
[3]  
Jasty M, 1996, CLIN ORTHOP RELAT R, P165
[4]   The importance of leg length discrepancy after total hip arthroplasty [J].
Konyves, A ;
Bannister, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :155-157
[5]   Accuracy considerations in navigated cup placement for total hip arthroplasty [J].
Langlotz, U. ;
Gr tzner, P. A. ;
Bernsmann, K. ;
Kowal, J. H. ;
Tannast, M. ;
Caversaccio, M. ;
Nolte, L-P .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H7) :739-753
[6]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[7]   Leg length discrepancy after total hip arthroplasty [J].
Maloney, WJ ;
Keeney, JA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :108-110
[8]   Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system [J].
Miki, Hidenobu ;
Yamanashi, Wataru ;
Nishii, Takashi ;
Sato, Yoshinobu ;
Yoshikawa, Hideki ;
Sugano, Nobuhiko .
JOURNAL OF ARTHROPLASTY, 2007, 22 (07) :946-952
[9]   Evaluation of a new leg length measurement algorithm in hip arthroplasty [J].
Murphy, Stephen B. ;
Ecker, Timo M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :85-89
[10]   THE DEFINITION AND MEASUREMENT OF ACETABULAR ORIENTATION [J].
MURRAY, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :228-232