Assessment of the Inner Surface Roughness of 3D Printed Dental Crowns via Optical Coherence Tomography Using a Roughness Quantification Algorithm

被引:16
作者
Lee, Jaeyul [1 ]
Abu Saleah, Sm [1 ]
Jeon, Byeonggyu [1 ]
Wijesinghe, Ruchire Eranga [2 ,3 ]
Lee, Dong-Eun [4 ]
Jeon, Mansik [1 ]
Kim, Jeehyun [1 ]
机构
[1] Kyungpook Natl Univ, Coll IT Engn, Sch Elect Engn, Daegu 41566, South Korea
[2] Kyungil Univ, Coll Engn, Dept Biomed Engn, Gyongsan 38428, South Korea
[3] Kyungil Univ, Coll Smart Engn, Dept Autonomous Robot Engn, Gyongsan 38428, South Korea
[4] Kyungpook Natl Univ, Sch Architecture Civil Environm & Energy Engn, Daegu 41566, South Korea
基金
新加坡国家研究基金会;
关键词
Dentistry; Rough surfaces; Surface roughness; Three-dimensional displays; Surface topography; Surface treatment; Imaging; 3D printing; dental crown; image processing; optical coherence tomography; surface roughness; HUMAN GINGIVAL SULCUS; MICROSCOPY; PROSTHESES; INSPECTION; ACCURACY; HARD;
D O I
10.1109/ACCESS.2020.3011136
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Dental crowns are used to restore decayed or chipped teeth, where their surfaces play a key role in this restoration process, as they affect the fitting and stable bonding of the prostheses. The surface texture of crowns can interfere with this restoration process, therefore the measurement of their inner surface roughness is very important but difficult to achieve using conventional imaging methods. In this study, the inner surfaces of dental crowns were three-dimensionally (3D) visualized using swept-source optical coherence tomography (SS-OCT) system. Nine crowns were fabricated with a commercial 3D printer using three different hatching methods (one-way, cross, and 30 degrees angle counter-clockwise) and three different build direction angles (0 degrees, 45 degrees, and 90 degrees). In addition, an image processing algorithm was developed, which uses morphological filtering, boundary detection, and a high-pass frequency filtering technique, to quantitatively evaluate the inner surface roughness of the dental crowns cross-sections with the depth-of-focus set to match two different regions. The averaged smoothness of fabricated crown was effectively produced using the cross-hatching and the build direction angle of 90 degrees by the respective process. Thus, the results confirm the potential use of this methodology to determine the best parameters to use in 3D fabrication for improving the effectiveness and stability of dental prostheses.
引用
收藏
页码:133854 / 133864
页数:11
相关论文
共 50 条
  • [31] Investigation on surface roughness of injection molded polypropylene parts with 3D optical metrology
    Gangjian Guo
    International Journal on Interactive Design and Manufacturing (IJIDeM), 2022, 16 : 17 - 23
  • [32] Optimization of process parameters and evaluation of surface roughness for 3D printed nylon-aramid composite
    Nagendra, J.
    Srinath, M. K.
    Sujeeth, S.
    Naresh, K. S.
    Prasad, M. S. Ganesha
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 674 - 682
  • [33] Numerical Simulation of Forced Convection in a Microchannel with Realistic Roughness of 3D Printed Surface
    Manavi, Seyed Alborz
    Kenig, Eugeny Y.
    29TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PT A, 2019, 46 : 823 - 828
  • [34] Evaluation of mathematical models for surface roughness prediction of PolyJet 3D printed parts
    Pandey, Praneet
    Nayak, Ankit
    Taufik, Mohammad
    ADVANCES IN MATERIALS AND PROCESSING TECHNOLOGIES, 2024, 10 (01) : 89 - 98
  • [35] Microstructural properties and surface roughness of 3D printed open cell-foam
    Anuar, Fadhilah Shikh
    Mustapha, Khairul Azhar
    Sa'at, Fatimah Al-Zahrah Mohd
    Zini, Nurul Hilwa Mohd
    Tokit, Ernie Mat
    Narasimmanaidu, Satishwara Rao
    Hooman, Kamel
    JURNAL TRIBOLOGI, 2023, 36 : 16 - 31
  • [36] Effect of Different Finishing Systems on Surface Roughness and Gloss of a 3D-Printed Material for Permanent Dental Use
    Vichi, Alessandro
    Balestra, Dario
    Louca, Chris
    APPLIED SCIENCES-BASEL, 2024, 14 (16):
  • [37] The Influence of Process Parameters on the Surface Roughness of a 3D-Printed Co-Cr Dental Alloy Produced via Selective Laser Melting
    Hong, Min-Ho
    Min, Bong Ki
    Kwon, Tae-Yub
    APPLIED SCIENCES-BASEL, 2016, 6 (12):
  • [38] Surface roughness comparison between printed parts manufactured via open source and commercial 3D printing machine
    Dong, Lim Guo
    bin Alkahari, Mohd Rizal
    bin Ramli, Faiz Redza
    Sudin, Mohd Nizam
    PROCEEDINGS OF INNOVATIVE RESEARCH AND INDUSTRIAL DIALOGUE 2018 (IRID'18), 2019, : 190 - 191
  • [39] Generalized 3D registration algorithm for enhancing retinal optical coherence tomography images
    Tse, Tiffany
    Chen, Yudan
    Siadati, Mahsa
    Miao, Yusi
    Song, Jun
    Ma, Da
    Mammo, Zaid
    Ju, Myeong Jin
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (06)
  • [40] Effect of smokeless tobacco on color stability and surface roughness of CAD/CAM milled, 3D printed, and conventional provisional crown and fixed dental prosthesis materials: An in vitro study
    Sayed, Mohammed E.
    Jain, Saurabh
    Jokhadar, Hossam F.
    Alshahrani, Ahid Amer
    AlResayes, Saad Saleh
    Alqahtani, Saeed M.
    Alqarni, Hatem
    Anab, Najwa Ali
    Alsubeaie, Nouf H.
    Alsubaie, Shaa H.
    Khalid, Asaad
    Franco, Rocco
    Minervini, Giuseppe
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (03) : 1697 - 1711