Reevaluating multicolor flow cytometry to assess microbial viability

被引:44
|
作者
Buysschaert, Benjamin [1 ]
Byloos, Bo [1 ,2 ]
Leys, Natalie [2 ]
Van Houdt, Rob [2 ]
Boon, Nico [1 ]
机构
[1] Univ Ghent, CMET, Coupure Links 653, B-9000 Ghent, Belgium
[2] Belgian Nucl Res Ctr SCK CEN, Microbiol Unit, Boeretang 200, B-2400 Mol, Belgium
关键词
Functionality; Protocols; Viability; SYTO; Multicolor FCM; ESCHERICHIA-COLI O157-H7; FED-BATCH CULTURES; NUCLEIC-ACID DYES; BACTERIAL VIABILITY; PHYSIOLOGICAL-STATE; PROPIDIUM IODIDE; NILE RED; BACILLUS-LICHENIFORMIS; SUCCINIMIDYL ESTER; LACTOCOCCUS-LACTIS;
D O I
10.1007/s00253-016-7837-5
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Flow cytometry is a rapid and quantitative method to determine bacterial viability. Although different stains can be used to establish viability, staining protocols are inconsistent and lack a general optimization approach. Very few "true" multicolor protocols, where dyes are combined in one sample, have been developed for microbiological applications. In this mini-review, the discrepancy between protocols for cell-permeant nucleic acid and functional stains are discussed as well as their use as viability dyes. Furthermore, optimization of staining protocols for a specific setup are described. Original data using the red-excitable SYTO dyes SYTO 59 to 64 and SYTO 17, combined with functional stains, for double and triple staining applications is also included. As each dye and dye combination behaves differently within a certain combination of medium matrix, microorganism, and instrument, protocols need to be tuned to obtain reproducible results. Therefore, single, double, and triple stains are reviewed, including the different parameters that influence staining such as stain kinetics, optimal stain concentration, and the effect of the chelator EDTA as membrane permeabilizer. In the last section, we highlight the need to investigate the stability of multicolor assays to ensure correct results as multiwell autoloaders are now commonly used.
引用
收藏
页码:9037 / 9051
页数:15
相关论文
共 50 条
  • [31] Multicolor flow cytometry in clinical samples for platelet signaling assessment
    Garcia, Cedric
    Dejean, Sebastien
    Savy, Nicolas
    Bordet, Jean-Claude
    Series, Jennifer
    Cadot, Sarah
    Ribes, Agnes
    Voisin, Sophie
    Rugeri, Lucia
    Payrastre, Bernard
    Sie, Pierre
    RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2023, 7 (04)
  • [32] Thematic workshop on fluorescence compensation settings in multicolor flow cytometry
    Bayer, Jan
    Grunwald, Didier
    lambert, Claude
    Mayol, Jean Francois
    Maynadie, Marc
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2007, 72B (01) : 8 - 13
  • [33] IS MULTICOLOR FLOW CYTOMETRY DIAGNOSTIC AND PRONOSTIC AT THE ACUTE PHASE OF SEPSIS?
    Bellier, R.
    Guerin, E.
    Perrodeau, E.
    Orabona, M.
    Couve-Deacon, E.
    Vallejo, C.
    Pichon, N.
    Cypierre, A.
    Feuillard, J.
    Francois, B.
    INTENSIVE CARE MEDICINE, 2011, 37 : S142 - S142
  • [34] Establishment of a Protocol For Multicolor Flow Cytometry Of Porcine Skin Cells
    Clayton, Shannon M.
    Yang, Hsin-ya
    Recendez, Cynthia
    Zhu, Kan
    Villa-Martinez, Guillermo
    Gallegos, Anthony
    Zhao, Min
    Isseroff, Rivkah
    Soulika, Athena
    WOUND REPAIR AND REGENERATION, 2024, 32 (04) : 590 - 590
  • [35] Application of multicolor flow cytometry in liquid biopsy of breast cancer
    Kaigorodova, E., V
    Grishchenko, M. Yu
    BYULLETEN SIBIRSKOY MEDITSINY, 2023, 22 (03): : 165 - 170
  • [36] Characterization of lymphocyte populations in different organs by multicolor flow cytometry
    Baumgart, A.
    Schulte, R.
    Stahl-Hennig, C.
    Sopper, S.
    CYTOMETRY PART A, 2007, 71A (01) : 51 - 51
  • [37] Assessment of activated sludge viability with flow cytometry
    Ziglio, G
    Andreottola, G
    Barbesti, S
    Boschetti, G
    Bruni, L
    Foladori, P
    Villa, R
    WATER RESEARCH, 2002, 36 (02) : 460 - 468
  • [38] Assessment of Helicobacter pylori viability by flow cytometry
    Sarafnejad, A.
    Siavoshi, F.
    Safaralizadeh, R.
    Masarat, S.
    Khosravi, F.
    Malekzadeh, R.
    Nikbin, B.
    Salehi-Nodeh, A. R.
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2007, 36 (01) : 50 - 54
  • [39] A NOVEL AND INEXPENSIVE SOURCE OF ALLOPHYCOCYANIN FOR MULTICOLOR FLOW-CYTOMETRY
    JUNG, TM
    DAILEY, MO
    JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 121 (01) : 9 - 18
  • [40] Detection of multiple myeloma cells using multicolor flow cytometry
    Kara, IO
    Sahin, B
    JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (14) : 602S - 602S