Monitoring and Control of Medical Air Disinfection Parameters of Nosocomial Infection System Based on Internet of Things

被引:17
作者
Yang, Liu [1 ]
Yao, Tianling [2 ]
Liu, Guiting [3 ]
Sun, Limei [4 ]
Yang, Na [5 ]
Zhang, He [1 ]
Zhang, Shuli [1 ]
Yang, Yueguang [1 ]
Pang, Yaqiu [1 ]
Liu, Xiaohong [1 ]
Hou, Xianming [6 ]
机构
[1] Mudanjiang Med Univ, Cent Sterile Supply Dept, Affiliated Hongqi Hosp, Mudanjiang 157011, Heilongjiang, Peoples R China
[2] Mudanjiang Med Univ, Dept Emergency, Affiliated Hongqi Hosp, Mudanjiang 157011, Heilongjiang, Peoples R China
[3] Mudanjiang Med Univ, Dept Thorac Surg, Affiliated Hongqi Hosp, Mudanjiang 157011, Heilongjiang, Peoples R China
[4] Mudanjiang Canc Hosp, Radiotherapy Subjects 2, Mudanjiang 157000, Heilongjiang, Peoples R China
[5] Mudanjiang Med Univ, Affiliated Hongqi Hosp, Endocrine Dept, Mudanjiang 157011, Heilongjiang, Peoples R China
[6] Mudanjiang Med Univ, Affiliated Hongqi Hosp, Infect Management Sect, 5 Tongxiang Rd, Mudanjiang 157011, Heilongjiang, Peoples R China
关键词
Circulating air volume; Sensor; Parameter detection; Management software; Internet of things;
D O I
10.1007/s10916-019-1205-9
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
To include the two key parameters of circulating air volume and instantaneous ultraviolet illuminance, as well as the minor influencing factors such as temperature, humidity, comings and goings of personnel and other parameters into the scope of conventional monitoring, and monitor and alarm each parameter, the key problem is to design the data transmission of sensors of existing products and debug the network management system, and solve every problem in the research process through the cycle of experiment-trial-experiment. The specific functions of a single instrument and system software can be achieved by solving the key links such as type selection of various sensors, circuit interface, guarantee measures for measurement accuracy of various parameters, research and development of networked air disinfection management system software, design of WiFi interface, cost control of single machine and system and so on. And ultraviolet luminance sensors can be used to monitor the ultraviolet intensity in the machine in real time, and monitor 7 parameters, including circulating air volume, ozone concentration, comings and goings of personnel, temperature, humidity and leaked ultraviolet intensity.
引用
收藏
页数:7
相关论文
共 7 条
[1]  
Balikhin IL, 2016, BIOMED ENG, V49, P389, DOI [10.1007/s10527-016-9573-7, DOI 10.1007/S10527-016-9573-7]
[2]   A Modular IoT Platform for Real-Time Indoor Air Quality Monitoring [J].
Benammar, Mohieddine ;
Abdaoui, Abderrazak ;
Ahmad, Sabbir H. M. ;
Touati, Farid ;
Kadri, Abdullah .
SENSORS, 2018, 18 (02)
[3]   Enhanced visible-light-induced photocatalytic disinfection of E-coli by carbon-sensitized nitrogen-doped titanium oxide [J].
Li, Qi ;
Xie, Rongcai ;
Ll, Yin Wai ;
Mintz, Eric A. ;
Shang, Jian Ku .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (14) :5050-5056
[4]   Air-Abrasive Disinfection of Implant Surfaces in a Simulated Model of Periimplantitis [J].
Quintero, David George ;
Taylor, Robert Bonnie ;
Miller, Matthew Braden ;
Merchant, Keith Roshanali ;
Pasieta, Scott Anthony .
IMPLANT DENTISTRY, 2017, 26 (03) :423-428
[5]   "Effectiveness of a shielded ultraviolet C air disinfection system in an inpatient pharmacy of a tertiary care children's hospital" Lacks scientific evidence [J].
Roth, Abby ;
Douglass, Kate ;
Wagner, James .
AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (06) :730-731
[6]   Assessment of air and water contamination by disinfection by-products at 41 indoor swimming pools [J].
Tardif, Robert ;
Catto, Cyril ;
Haddad, Sami ;
Simard, Sabrina ;
Rodriguez, Manuel .
ENVIRONMENTAL RESEARCH, 2016, 148 :411-420
[7]   Middle mesial canals in mandibular first molars: A micro-CT study in different populations [J].
Versiani, Marco Aurelio ;
Ordinola-Zapata, Ronald ;
Keles, Ali ;
Alcin, Hatice ;
Bramante, Clovis Monteiro ;
Pecora, Jesus Djalma ;
Sousa-Neto, Manoel Damiao .
ARCHIVES OF ORAL BIOLOGY, 2016, 61 :130-137