Dosimetry of high intensity electron beams produced with dedicated accelerators in Intra-Operative Radiation Therapy (IORT)

被引:0
|
作者
Lamanna, E. [1 ,6 ]
Fiorillo, A. S. [1 ,6 ]
Bruno, C. [2 ]
Santaniello, A. [2 ]
Siaka, Y. F. T. [2 ,3 ]
Berdondini, A. [4 ]
Bettuzzi, M. [4 ]
Brancaccio, R. [4 ]
Casali, F. [4 ]
Morigi, M. P. [4 ]
Barca, G. [5 ]
Castrovillari, F. [5 ]
机构
[1] Magna Graecia Univ Catanzaro, Fac Med, I-88100 Catanzaro, Italy
[2] Univ Calabria, Dept Phys, Cosenza, Italy
[3] Univ Douala, Ctr Atom Mol Phys & Quantum Opt, Douala, Cameroon
[4] Univ Bologna, Dept Phys, INFN, Bologna, Italy
[5] Azienda Ospedaliera, Med Phys, Cosenza, Italy
[6] INFN, Gruppo Collegato, Cosenza, Italy
关键词
IORT; dosimetry; scintillating fibers; depthdose; measurement; 3D;
D O I
10.1109/NSSMIC.2007.4436435
中图分类号
O59 [应用物理学];
学科分类号
摘要
The technique of High Dose Intra-Operative Radiation Therapy (HDR-IORT) consists in the delivery of irradiation immediately following the removal of a cancerous mass, where the same incision is used to direct the radiation to the tumour bed. Given its particular characteristics, IORT requires dose measurements that are different from those requested in external radiotherapy treatments. The main reason lies in the fact that in this case a single high dose must be delivered to a volume target whose extension and depths Will be determined directly during the operation. Since the possibility of devising a treatment plan using a TPS (Treatment Planning System) is not available, it is necessary to know the physical and geometric characteristics of the beam. Defining the physical characteristics of the beam entails both measuring the delivered dose and defining (monitoring) procedures. In any case a much higher dose will be released than occurs with conventional external accelerators. The ionization chamber recommended by the standard protocols for radiotherapy cannot be used because of the ion recombination inside the gas. In this work we propose the use of a calorimetric phantom, the Dosiort, to measure the beam properties. We describe the main characteristics and some preliminary results of the Dosiort System, which is proposed within the framework of a research project of the INFN (Italian National Institute of Nuclear Physics). The set-up is a solid phantom of density approaching 1 g/cc with sensitive layers of scintillating fibres at fixed a position in a calorimetric configuration for the containment of electrons of energy 4-12 MeV. The prototype will be able to define the physical and geometrical characteristics of the electron beam (quality, isotropy, homogeneity, etc) and to measure the parameters needed to select the energy, the intensity and the Monitor Units (MU) for the exposition: Percentage Depth Dose; Beam profiles; Isodose curves; Values of dose for MU.
引用
收藏
页码:732 / 738
页数:7
相关论文
共 50 条
  • [21] Intra-operative radiation therapy for osteosarcoma in the extremities
    Tsuboyama, T
    Toguchida, J
    Kotoura, Y
    Kasahara, K
    Hiraoka, M
    Nakamura, T
    INTERNATIONAL ORTHOPAEDICS, 2000, 24 (04) : 202 - 207
  • [22] Robotically Assisted Intra-Operative Radiation Therapy
    Vaghefi, Houman
    Stone, Pamela
    Wheeler, James
    Lowden, John
    Korda, Samantha
    Sparks, Irina
    Darnell, Grace
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2021, 44 (10): : S77 - S77
  • [23] Study and realization of Real-Time, in-depth dosimetry system for IORT (Intra Operative Radiation Therapy)
    Brancaccio, R.
    Bettuzzi, M.
    Casali, F.
    Morigi, M. P.
    Berdondini, A.
    Bruno, C.
    Siaka, Y. F. Tchuente
    Santamello, A.
    Lamanna, E.
    Fiorillo, A. S.
    Barca, G.
    Castrovillari, F.
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS IX, 2007, 6706
  • [24] Analysis of dose characteristics from beveled and flat applicators in intra-operative radiation therapy (IORT) using Monte Carlo simulation, Wellhofer measurement and film dosimetry
    Parsai, E
    Li, J
    Feldmeier, J
    Schifter, D
    Priyadershi, A
    Dobelbower, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1420 - 1420
  • [25] Intra-operative radiation therapy in tumors of the digestive tract
    Dubois, JB
    BULLETIN DU CANCER, 2001, 88 (02) : 155 - 162
  • [26] Dosimetry for New Radiation Therapy Approaches Using High Energy Electron Accelerators
    Kokurewicz, Karolina
    Schuller, Andreas
    Brunetti, Enrico
    Subiel, Anna
    Kranzer, Rafael
    Hackel, Thomas
    Meier, Markus
    Kapsch, Ralf-Peter
    Jaroszynski, Dino A.
    FRONTIERS IN PHYSICS, 2020, 8
  • [27] Dosimetry for New Radiation Therapy Approaches Using High Energy Electron Accelerators
    Kokurewicz, Karolina
    Schüller, Andreas
    Brunetti, Enrico
    Subiel, Anna
    Kranzer, Rafael
    Hackel, Thomas
    Meier, Markus
    Kapsch, Ralf-Peter
    Jaroszynski, Dino A.
    Frontiers in Physics, 2020, 8
  • [28] SUMMARY OF THE WORKSHOP ON INTRA-OPERATIVE RADIATION-THERAPY
    TEPPER, J
    SINDELAR, W
    CANCER TREATMENT REPORTS, 1981, 65 (9-10): : 911 - 918
  • [29] Dependence of Induced Biological Damage on the Energy Distribution and Intensity of Clinical Intra-Operative Radiotherapy Electron Beams
    Colmenares, Rafael
    Carrion-Marchante, Rebeca
    Martin, M. Elena
    Munoz, Laura Salinas
    Garcia-Bermejo, Maria Laura
    Oller, Juan C.
    Munoz, Antonio
    Blanco, Francisco
    Rosado, Jaime
    Lozano, Ana I.
    alvarez, Sofia
    Garcia-Vicente, Feliciano
    Garcia, Gustavo
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (13)
  • [30] NEOADJUVANT RADIO-CHEMOTHERAPY WITH INTRA-OPERATIVE RADIATION THERAPY (IORT) IN RESECTED ESOPHAGEAL SQUAMOUS CARCINOMA: FEASIBILITY AND OUTCOME
    Gonzalez-Domingo, M.
    Calvo, F.
    Garcia-Sabrido, J. L.
    Obregon, R.
    Gomez-Espi, M.
    Lozano, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : IX - X