The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement - Results at five to fourteen years

被引:47
作者
Lachiewicz, PF [1 ]
Soileau, ES [1 ]
机构
[1] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27599 USA
关键词
D O I
10.2106/00004623-200403000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: osteolysis and increased polyethylene wear have been reported in association with several designs of modular total knee prostheses. The purpose of the present study was to evaluate a modular posterior stabilized prosthesis to determine its clinical performance as well as the rates of component loosening and osteolysis. Methods: We performed a prospective, consecutive study of 193 knees in 131 patients who were managed with the modular Insall-Burstein 11 posterior stabilized total knee prosthesis by one surgeon. The mean age of the patients at the time of surgery was sixty-eight years, and the mean duration of follow-up was seven years (range, five to fourteen years). Clinical evaluation was performed with use of standard knee-scoring systems. Radiographs were evaluated for the presence of radiolucent lines, osteolysis, and loosening. Results: The overall result (as determined with the Hospital for Special Surgery scoring system) was rated as excellent for 112 knees, good for sixty, fair for fifteen, and poor for six. The mean postoperative flexion was 112degrees. No clinical or radiographic loosening of the tibial component was noted. Eight knees had osteolytic lesions of the tibia. Thin, incomplete, nonprogressive radiolucent lines were noted around thirty tibial components (16%). There were three reoperations. Conclusions: Despite previous reports of osteolysis, polyethylene wear, and loosening in association with some modular total knee implant designs, there was no loosening in this series of posterior stabilized total knee replacements and only eight knees had tibial osteolysis after a mean duration of follow-up of seven years. We believe that total knee arthroplasties that are performed with use of cemented modular posterior stabilized components can have a high rate of intermediate-term success. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:525 / 530
页数:6
相关论文
共 23 条
[1]  
BERRY DJ, 1993, CLIN ORTHOP RELAT R, P204
[2]   THE POSTERIOR STABILIZED TOTAL KNEE PROSTHESIS - ASSESSMENT OF POLYETHYLENE DAMAGE AND OSTEOLYSIS AFTER A 10-YEAR-MINIMUM FOLLOW-UP [J].
COLIZZA, WA ;
INSALL, JN ;
SCUDERI, GR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) :1713-1720
[3]  
DANNENMAIER WC, 1985, CLIN ORTHOP RELAT R, P224
[4]  
Engh G A, 2001, Instr Course Lect, V50, P391
[6]   POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES [J].
ENGH, GA ;
DWYER, KA ;
HANES, CK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :9-17
[7]  
ENGH GA, 1994, CLIN ORTHOP RELAT R, P33
[8]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[9]   Osteolysis associated with cemented total knee arthroplasty [J].
Griffin, FM ;
Scuderi, GR ;
Gillis, AM ;
Li, S ;
Jimenez, E ;
Smith, T .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :592-598
[10]   OSTEOLYTIC CYST-LIKE AREA ASSOCIATED WITH POLYETHYLENE AND METALLIC DEBRIS AFTER TOTAL KNEE REPLACEMENT WITH AN UNCEMENTED VITALLIUM PROSTHESIS - A CASE-REPORT [J].
GROSS, TP ;
LENNOX, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1096-1101