Effect of Left Atrial Wall Thickness on Radiofrequency Ablation Success

被引:26
作者
Inoue, Jiro [1 ]
Skanes, Allan C. [2 ]
Gula, Lorne J. [2 ]
Drangova, Maria [1 ,3 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, 1151 Richmond St N, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Div Cardiol, Dept Med, London, ON, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大健康研究院;
关键词
atrial fibrillation; CT scan; electrical reconnection; left atrium; radiofrequency catheter ablation; wall thickness; ESOPHAGEAL FISTULA; CATHETER ABLATION; COMPUTED-TOMOGRAPHY; FIBRILLATION; COMPLICATION; EFFICACY; FAT;
D O I
10.1111/jce.13065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Effect of LA Wall Thickness on RF Ablation IntroductionRadiofrequency (RF) ablation in thicker regions of the left atrium (LA) may require increased ablation energy in order to achieve effective transmural lesions. Consequently, many cases of recurrent atrial fibrillation (AF) postablation may be due to thicker-than-normal atrial tissue. The aim of this study was to test the hypotheses that patients with recurrent AF have thicker tissue overall and that electrical reconnection is more likely in regions of thicker tissue. Methods and ResultsRetrospective analysis was performed on 86 CT images acquired preoperatively from a cohort of 119 patients who had undergone RF ablation for AF. Of these, 33 patients experienced recurrence of AF within 1 year of initial treatment and 29 returned for a repeat ablation. For each patient, LA wall thickness (LAWT) was measured from the images in 12 anatomical regions using custom software. Patients with recurrent AF had larger LAWT compared to successfully treated patients (1.6 0.6 mm vs. 1.5 +/- 0.5 mm, P < 0.001) and reconnection was found to be at regions of thicker tissue (1.6 +/- 0.6mm, P = 0.038) compared to nonreconnected regions (1.5 +/- 0.5 mm). The superior right posterior wall of the LA was significantly related to both recurrence (P = 0.048) and reconnection (P = 0.014). ConclusionIncreased LAWT has a small but significant effect on postablation recurrence and reconnection. Measures of LAWT may facilitate appropriate dosing of RF energy, but other factors will be critical in transmural lesion formation and ablation success.
引用
收藏
页码:1298 / 1303
页数:6
相关论文
共 17 条
[1]   Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation [J].
Abbara, S ;
Desai, JC ;
Cury, RC ;
Butler, J ;
Nieman, K ;
Reddy, V .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :417-422
[2]   Efficacy of repeat pulmonary vein isolation procedures in patients with recurrent atrial fibrillation [J].
Callans, DJ ;
Gerstenfeld, EP ;
Dixit, S ;
Zado, E ;
Vanderhoff, M ;
Ren, JF ;
Marchlinski, FE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (09) :1050-1055
[3]   Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation [J].
Cappato, Riccardo ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Davies, Wyn ;
Iesaka, Yoshito ;
Kalman, Jonathan ;
Kim, You-Ho ;
Klein, George ;
Natale, Andrea ;
Packer, Douglas ;
Skanes, Allan ;
Ambrogi, Federico ;
Biganzoli, Elia .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) :32-38
[4]   Use of Computed Tomography to Identify Atrial Fibrillation Associated Differences in Left Atrial Wall Thickness and Density [J].
Dewland, Thomas A. ;
Wintermark, Max ;
Vaysman, Anna ;
Smith, Lisa M. ;
Tong, Elizabeth ;
Vittinghoff, Eric ;
Marcus, Gregory M. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (01) :55-62
[5]   Design and Evaluation of a Catheter Contact-Force Controller for Cardiac Ablation Therapy [J].
Gelman, Daniel ;
Skanes, Allan C. ;
Tavallaei, Mohammad A. ;
Drangova, Maria .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (11) :2301-2307
[6]   Pulmonary Vein Isolation With Incomplete Antral Ablation Lines: Is More Ablation Necessary? Results of a Randomized Trial [J].
Gula, Lorne J. ;
Leong-Sit, Peter ;
Manlucu, Jaimie ;
Hillock, Lindsay ;
Yee, Raymond ;
Tang, Anthony S. L. ;
Klein, George J. ;
Skanes, Allan C. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (03) :298-302
[7]   Variation in left atrial transmural wall thickness at sites commonly targeted for ablation of atrial fibrillation [J].
Hall, Burr ;
Jeevanantham, Vinodh ;
Simon, Rochelle ;
Filippone, John ;
Vorobiof, Gabriel ;
Daubert, James .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 17 (02) :127-132
[8]   Left atrial wall thickness and outcomes of catheter ablation for atrial fibrillation in patients with hypertrophic cardiomyopathy [J].
Hayashi, Hiroshi ;
Hayashi, Meiso ;
Miyauchi, Yasushi ;
Takahashi, Kenta ;
Uetake, Shunsuke ;
Tsuboi, Ippei ;
Yodogawa, Kenji ;
Iwasaki, Yu-Ki ;
Shimizu, Wataru .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 40 (02) :153-160
[9]  
Ho SY, 1999, J CARDIOVASC ELECTR, V10, P1525
[10]   Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation [J].
Pappone, C ;
Oral, H ;
Santinelli, V ;
Vicedomini, G ;
Lang, CC ;
Manguso, F ;
Torracca, L ;
Benussi, S ;
Alfieri, O ;
Hong, R ;
Lau, W ;
Hirata, K ;
Shikuma, N ;
Hall, B ;
Morady, F .