Stochastic Dynamic Electrospray Ionization Mass Spectrometric Quantitative Analysis of Metronidazole in Human Urine

被引:6
作者
Ivanova, Bojidarka [1 ]
Spiteller, Michael [1 ]
机构
[1] Univ Dortmund, Inst Umweltforsch, Fak Chem & Chem Biol, Lehrstuhl Analyt Chem, Otto Hahn Str 6, D-44221 Dortmund, Nordrhein Westf, Germany
关键词
Mass spectrometry; Diffusion; Stochastic dynamics; Urine; Quantitative analysis; Metronidazole; PERFORMANCE LIQUID-CHROMATOGRAPHY; QUANTIFICATION; PLASMA; SILAC; CHLORAMPHENICOL; IDENTIFICATION; PREDICTION; PROTEOMICS; ACCURACY; RESIDUES;
D O I
10.1080/22297928.2022.2086822
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The study reports quantification of metronidazole (MTZ) in clinical human urine employing our innovative stochastic dynamic equation D"(SD) =2.6388.10(-17).(-). There are direct analysis without presence of internal standard, using ultra-high accuracy nano-electrospray ionization (ESI) mass spectrometry (MS), quantum chemistry and chemometrics, respectively. The linear calibration D"(SD) =f(conc.) equations are obtained for concentration range 2.5 to 25000 ng.(mL)(-1) of spiked urine samples, examining analyte MS ions at m/z 171.099(8), 172.071(8), 172.040(81), 213.146(3), 181.07(22) and 151.111(4), respectively. There is achieved exact coefficient of linear correlation (|r|=1) between theory and experiment of ion at m/z 172.0408(1). The major challenge to quantify MTZ in urine sample is that it stabilizes cations [M+H](+) of two tautomers, which equilibrium varies drastically within the standard linear calibration dynamic range. The fragmentation patterns depend on analyte tautomers and it unambiguous assignment in multicomponent samples with complex sample matrix effect (SME) is unable to be made without mediation to an independent physico-chemical law. To solve the problem, herein, is used, again, above equation, which is designed a bridge between quantitative and multidimensional structural analytical chemistry, when is used complementary with Arrhenius's quantum chemical diffusion parameter (D-QC.) There is achieved |r|=0.98 of D"(SD)=f(D-QC') examining tautomeric molecular and fragment ions of MTZ.
引用
收藏
页码:322 / 348
页数:27
相关论文
共 87 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   Retention Time Prediction Improves Identification in Nontargeted Lipidomics Approaches [J].
Aicheler, Fabian ;
Li, Jia ;
Hoene, Miriam ;
Lehmann, Rainer ;
Xu, Guowang ;
Kohlbacher, Oliver .
ANALYTICAL CHEMISTRY, 2015, 87 (15) :7698-7704
[3]   Direct nano-electrospray ionization tandem mass spectrometry for the quantification and identification of metronidazole in its dosage form and human urine [J].
Amer, Sara ;
Zarad, Walaa ;
El-Gindy, Heba ;
Abdel-Salam, Randa ;
Hadad, Ghada ;
Masujima, Tsutomu ;
Emara, Samy .
ROYAL SOCIETY OPEN SCIENCE, 2019, 6 (11)
[4]  
[Anonymous], 1990, OFFICIAL J EUROPEAN, VL224, P2
[5]   The PredictAD project: development of novel biomarkers and analysis software for early diagnosis of the Alzheimer's disease [J].
Antila, Kari ;
Lotjonen, Jyrki ;
Thurfjell, Lennart ;
Laine, Jarmo ;
Massimini, Marcello ;
Rueckert, Daniel ;
Zubarev, Roman A. ;
Oresic, Matej ;
van Gils, Mark ;
Mattila, Jussi ;
Simonsen, Anja Hviid ;
Waldemar, Gunhild ;
Soininen, Hilkka .
INTERFACE FOCUS, 2013, 3 (02)
[6]   Quantification of the N-glycosylated Secretome by Super-SILAC During Breast Cancer Progression and in Human Blood Samples [J].
Boersema, Paul J. ;
Geiger, Tamar ;
Wisniewski, Jacek R. ;
Mann, Matthias .
MOLECULAR & CELLULAR PROTEOMICS, 2013, 12 (01) :158-171
[7]   Spot urine collection: A valid alternative to total urine collection for metabolomic studies in dairy cattle [J].
Boudra, H. ;
Noziere, P. ;
Cantalapiedra-Hijar, G. ;
Traikia, M. ;
Martin, J-F. ;
Petera, M. ;
Lagree, M. ;
Doreau, M. ;
Morgavi, D. P. .
JOURNAL OF DAIRY SCIENCE, 2022, 105 (01) :301-312
[8]  
Branton A., 2020, J ADV MED PHARM SCI, V20, P40
[9]  
Bulska E., 2018, METROLOGY CHEM
[10]   Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation [J].
Chen, HW ;
Venter, A ;
Cooks, RG .
CHEMICAL COMMUNICATIONS, 2006, (19) :2042-2044