Laboratory characterization of sandy soil water content during drying process using electrical resistivity/resistance method (ERM)

被引:10
作者
An, Ni [1 ,2 ]
Tang, Chao-Sheng [1 ]
Cheng, Qing [1 ]
Wang, De-Yin [1 ]
Shi, Bin [1 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, 163 Xianlin Ave, Nanjing 210023, Peoples R China
[2] Cardiff Univ, Geoenvironm Res Ctr, Cardiff Sch Engn, Newport Rd, Cardiff CF24 3AA, Wales
基金
中国国家自然科学基金;
关键词
Soil water evaporation; Soil water content; Electrical resistivity; resistance method (ERM); Evaporation front; Temperature effect; BARE-SOIL; DC RESISTIVITY; CLAYEY SOIL; TEMPERATURE-CHANGES; EVAPORATIVE FLUXES; SURFACE-RESISTANCE; NUMERICAL-ANALYSIS; SOLUTE TRANSPORT; TOMOGRAPHY ERT; CONDUCTIVITY;
D O I
10.1007/s10064-020-01805-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Drought-induced evaporation can reduce soil water content and significantly alter soil hydro-mechanical behavior. Understanding the temporal and spatial distribution characteristics of soil water content during evaporation is of great significance for evaluating the encountered geotechnical and geo-environmental problems in arid or semi-arid regions. In this study, an electrical resistivity/resistance method (ERM) with a high spatial resolution of centimeter-level was developed for a small-scale laboratory test and applied to quantitatively characterize the evaporation-induced water content variations along a depth gradient. A total of 8 groups of initially saturated sandy soil columns (84 mm in diameter and 290 mm in height) were prepared, and eight pairs of mini electrodes (3.5 mm in diameter) were installed in each soil sample with a vertical distance of 30 mm. The soil columns were subjected to continuous drying. The changes in soil electrical resistance at different depths were monitored by the electrode couples. The gravimetric water contents at different depths were also measured at the end of drying. It is found that soil water content decreases exponentially with increasing electrical resistance. Based on the obtained data, a calibration relationship between soil gravimetric water content and corrected electrical resistance was well established with consideration of temperature effect. This relationship was validated successfully by the experimental results, indicating the feasibility of the developed ERM to characterize the soil water content dynamics during the drying process. Besides, the drying process with the movement of the evaporation front was discussed. The results of this study demonstrate the good performance of ERM in the estimation of temporal and spatial variations of soil water content and its potential application in arid or semi-arid regions with frequent droughts.
引用
收藏
页码:4411 / 4427
页数:17
相关论文
共 93 条
  • [1] The Role of Water Content in Electrical Resistivity Tomography of a Vertisol
    Ackerson, Jason P.
    Morgan, Cristine L. S.
    Everett, Mark E.
    McInnes, Kevin J.
    [J]. SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2014, 78 (05) : 1552 - 1562
  • [2] Spatial and temporal monitoring of soil moisture using surface electrical resistivity tomography in Mediterranean soils
    Alamry, Abdulmohsen S.
    van der Meijde, Mark
    Noomen, Marleen
    Addink, Elisabeth A.
    van Benthem, Rik
    de Jong, Steven M.
    [J]. CATENA, 2017, 157 : 388 - 396
  • [3] Measurement of evaporation on bare soil and estimating surface resistance
    Aluwihare, S
    Watanabe, K
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2003, 129 (12): : 1157 - 1168
  • [4] Application of electrical resistivity method in the characterization of 2D desiccation cracking process of clayey soil
    An, Ni
    Tang, Chao-Sheng
    Cheng, Qing
    Wang, De-Yin
    Shi, Bin
    [J]. ENGINEERING GEOLOGY, 2020, 265
  • [5] Effects of soil characteristics on moisture evaporation
    An, Ni
    Tang, Chao-Sheng
    Xu, Shi-Kang
    Gong, Xue-Peng
    Shi, Bin
    Inyang, Hilary I.
    [J]. ENGINEERING GEOLOGY, 2018, 239 : 126 - 135
  • [6] Numerical investigation of water evaporation from Fontainebleau sand in an environmental chamber
    An, Ni
    Hemmati, Sahar
    Cui, Yu-jun
    Tang, Chao-sheng
    [J]. ENGINEERING GEOLOGY, 2018, 234 : 55 - 64
  • [7] Numerical analysis of soil volumetric water content and temperature variations in an embankment due to soil-atmosphere interaction
    An, Ni
    Hemmati, Sahar
    Cui, Yujun
    [J]. COMPUTERS AND GEOTECHNICS, 2017, 83 : 40 - 51
  • [8] Capacitance scaling system
    Aoki, T
    Yokoi, K
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 474 - 476
  • [9] The electrical resistivity log as an aid in determining some reservoir characteristics
    Archie, GE
    [J]. TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1942, 146 : 54 - 61
  • [10] Three-dimensional monitoring of soil water content in a maize field using Electrical Resistivity Tomography
    Beff, L.
    Guenther, T.
    Vandoorne, B.
    Couvreur, V.
    Javaux, M.
    [J]. HYDROLOGY AND EARTH SYSTEM SCIENCES, 2013, 17 (02) : 595 - 609