A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets

被引:22
作者
Cash, A
Curtis, R
Garrigia-Majo, D
McDonald, F
机构
[1] Kings Coll London, GKT Dent Inst, Dept Orthodont, London WC2R 2LS, England
[2] Kings Coll London, GKT Dent Inst, Dept Mat Sci, London WC2R 2LS, England
关键词
D O I
10.1093/ejo/26.1.105
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This ex vivo study compared the static and kinetic frictional resistance of eight different archwires tested in a single, stainless steel, zero base 0.022 x 0.028 inch (0.56 x 0.711 mm) slot standard edgewise bracket. The archwires evaluated were 0.019 x 0.025 inch (0.483 x 0.636 mm) in dimension, manufactured from the following alloys: beta titanium (TMA(TM)), 'low friction' coloured beta titanium (aqua, honeydew, purple and violet), ion-implanted beta titanium, Timolium(TM) and a stainless steel control. Prior to friction testing, bracket and archwire dimensions were measured by direct digital imaging via a desk-top computer linked to a binocular light microscope. Frictional force was evaluated using an Instron universal testing machine. All experiments were carried out at room temperature, with no ligation, in the dry state with 20 degrees of added torque. The results demonstrated that static and kinetic friction were statistically significant (P< 0.001) for all archwire types. Ion-implanted and standard TMA(TM) archwires were found to have no significant advantage over stainless steel. The archwire alloys may be ranked as follows: stainless steel produced the lowest frictional resistance followed by honeydew, ion-implanted TMA(TM) and Timolium(TM), with aqua, purple and violet producing frictional resistance values as high as standard TMA(TM). It was also found that the percentage difference between the archwire and bracket slot dimensions claimed by the manufacturers and those measured in this experiment produced tolerances ranging from +5.37 to -6.67 per cent.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 23 条
[1]   EVALUATION OF FRICTION FORCES IN 0.022X0.028 EDGEWISE BRACKET IN-VITRO [J].
ANDREASEN, GF ;
QUEVEDO, FR .
JOURNAL OF BIOMECHANICS, 1970, 3 (02) :151-+
[2]   EVALUATION OF FRICTION BETWEEN CERAMIC BRACKETS AND ORTHODONTIC WIRES OF 4 ALLOYS [J].
ANGOLKAR, PV ;
KAPILA, S ;
DUNCANSON, MG ;
NANDA, RS .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1990, 98 (06) :499-506
[3]  
Burstone C J, 1995, J Clin Orthod, V29, P453
[4]   FRICTIONAL FORCES BETWEEN BRACKET AND ARCH WIRE [J].
DRESCHER, D ;
BOURAUEL, C ;
SCHUMACHER, HA .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1989, 96 (05) :397-404
[5]   A COMPARATIVE-STUDY OF FRICTIONAL RESISTANCES BETWEEN ORTHODONTIC BRACKET AND ARCH WIRE [J].
FRANK, CA ;
NIKOLAI, RJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 78 (06) :593-609
[6]   A COMPARISON OF FRICTIONAL FORCES DURING SIMULATED CANINE RETRACTION OF A CONTINUOUS EDGEWISE ARCH WIRE [J].
GARNER, LD ;
ALLAI, WW ;
MOORE, BK .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1986, 90 (03) :199-203
[7]  
Ho K S, 1991, Aust Orthod J, V12, P95
[8]   EFFECT OF BRACKET AND WIRE COMPOSITION ON FRICTIONAL FORCES [J].
IRELAND, AJ ;
SHERRIFF, M ;
MCDONALD, F .
EUROPEAN JOURNAL OF ORTHODONTICS, 1991, 13 (04) :322-328
[9]  
Kajdas C., 1990, ENCY TRIBOLOGY
[10]   EVALUATION OF FRICTION BETWEEN EDGEWISE STAINLESS-STEEL BRACKETS AND ORTHODONTIC WIRES OF 4 ALLOYS [J].
KAPILA, S ;
ANGOLKAR, PV ;
DUNCANSON, MG ;
NANDA, RS .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1990, 98 (02) :117-126