Dynamic hip screw fixation of intertrochanteric fractures without using traction table

被引:3
|
作者
Kumar, Satish [1 ]
Chadha, Gaggan Naresh [1 ]
机构
[1] Sir Ganga Ram Hosp, DNB Orthopaed, New Delhi 110060, India
来源
ACTA ORTHOPAEDICA BELGICA | 2016年 / 82卷 / 02期
关键词
dynamic hip screw; traction table; hip fractures; polytrauma; TIP-APEX DISTANCE; FAILURE; FEMUR;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate a new technique of Dynamic hip screw (DHS) fixation without using traction table. From july 2006 to july 2012, 328 patients undergoing DHS fixation using manual traction technique were evaluated in terms of Tip apex distance (TAD), quality of fracture reduction, operation time, preoperative preparation time. In 97% cases good to moderate reduction could be achieved. The mean TAD was 19.2 millimeters, mean operation time 37 minutes and screw cutout rate was only 0.91 %. This technique is easy, reproducible, cheap do not sacrifice reduction alignment, screw position and is extremely beneficial in polytrauma patients where multiple surgeries are to be done.
引用
收藏
页码:346 / 350
页数:5
相关论文
共 50 条
  • [1] Dynamic Hip Screw Fixation of Intertrochanteric Fractures of Femur: A Comparison of Outcome With and Without Using Traction Table
    Gooi, S. G.
    Khoo, E. H.
    Ewe, Benny
    Yacoob
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2011, 5 (01) : 21 - 25
  • [2] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Leung, Frankie
    Gudushauri, Paata
    Yuen, Grace
    Lau, Tak-Wing
    Fang, Christian
    Chow, Shew-Ping
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03): : 302 - 306
  • [3] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Dhamangaonkar, Anoop C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 132 - 133
  • [4] Dynamic hip screw blade fixation for intertrochanteric hip fractures Reply
    Fang, Christian
    Leung, Frankie
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 133 - 133
  • [5] Salvage of failed dynamic hip screw fixation of intertrochanteric fractures
    Taheriazam, Afshin
    Saeidinia, Amin
    ORTHOPEDIC RESEARCH AND REVIEWS, 2019, 11 : 93 - 98
  • [6] Salvage of failed dynamic hip screw fixation of intertrochanteric fractures
    Said, GZ
    Farouk, O
    El-Sayed, A
    Said, HG
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (02): : 194 - 202
  • [7] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Yih-Shiunn Lee
    Hui-Ling Huang
    Ting-Ying Lo
    Chien-Rae Huang
    International Orthopaedics, 2007, 31 : 683 - 688
  • [8] Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate
    Mardani-Kivi, Mohsen
    Mirbolook, Ahmadreza
    Jahromi, Sina Khajeh
    Rad, Melina Rouhi
    TRAUMA MONTHLY, 2013, 18 (02) : 67 - 70
  • [9] Minimally Invasive Dynamic Hip Screw Fixation in Stable and Unstable Intertrochanteric Fractures
    Jana, Kanailal
    Jha, Dipak Kumar
    Chakraburtty, Tapas
    Mullick, Sunny Kumar
    Duttagupta, Swarnava
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (07) : 71 - 74
  • [10] To Study the Effectiveness and Safety of Dynamic Hip Screw (DHS) Fixation for Intertrochanteric Fractures
    Awan, Malik Mohammad Yasin
    Amjad, Mohammad
    Shah, Abdullah
    Ahmed, Ijaz
    Shad, Muhammad Nauman
    Fatima, Ajaz
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 342 - 345