Using two discrete frequencies within the middle infrared to quantitatively determine glucose in serum

被引:33
作者
Martin, WB
Mirov, S
Venugopalan, R
机构
[1] Univ Alabama, Dept Biomed Engn, Birmingham, AL 35294 USA
[2] Univ Alabama, Dept Phys, Birmingham, AL 35294 USA
关键词
glucose sensor; infrared spectroscopy; artificial pancreas; transmission;
D O I
10.1117/1.1501893
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Tight glucose monitoring is essential for the reduction of diabetic complications. This research investigated the changes of absorption spectra observed in serum at three prominent glucose absorption peaks in the middle infrared using a demountable liquid, transmission cell. Two frequencies of light were used to determine the glucose absorption: one at 1193 cm(-1) to determine the background water absorption and the other at one of the characteristic peaks (1035, 1080, and 1109 cm(-1)). The peak at 1035 cm(-1) was best for quantitative determination with a standard of error of 20.6 mg/dl (1.1 mmol/L). While interference from other serum constituents could cause problems, urea and albumin-two constituents known to have close absorption peaks-were determined to have no effect on the ability to determine the glucose levels at 1035 cm(-1). (C) 2002 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:613 / 617
页数:5
相关论文
共 40 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[3]   FOURIER-TRANSFORM INFRARED-SPECTROSCOPY OF SUGARS - STRUCTURAL-CHANGES IN AQUEOUS-SOLUTIONS [J].
BACK, DM ;
POLAVARAPU, PL .
CARBOHYDRATE RESEARCH, 1983, 121 (SEP) :308-311
[4]   Dynamic delay and maximal dynamic error in continuous biosensors [J].
Baker, DA ;
Gough, DA .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1292-1297
[5]   A glucose biosensor based on electrodeposited biocomposites of gold nanoparticles and glucose oxidase enzyme [J].
Bharathi, S ;
Nogami, M .
ANALYST, 2001, 126 (11) :1919-1922
[6]   Electrochemically mediated electrodeposition/electropolymerization to yield a glucose microbiosensor with improved characteristics [J].
Chen, XH ;
Matsumoto, N ;
Hu, YB ;
Wilson, GS .
ANALYTICAL CHEMISTRY, 2002, 74 (02) :368-372
[7]  
CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
[8]   Noninvasive and minimally-invasive optical monitoring technologies [J].
Coté, GL .
JOURNAL OF NUTRITION, 2001, 131 (05) :1596S-1604S
[9]   PHYSIOLOGICAL PREPARATION FOR STUDYING THE RESPONSE OF SUBCUTANEOUSLY IMPLANTED GLUCOSE AND OXYGEN SENSORS [J].
ERTEFAI, S ;
GOUGH, DA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (05) :362-368
[10]  
Guyton A. C., 1996, TXB MED PHYSL, P971