Digital radiography: The balance between image quality and required radiation dose

被引:153
作者
Uffmann, Martin [1 ]
Schaefer-Prokop, Cornelia [2 ]
机构
[1] Med Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[2] Acad Med Ctr, NL-1105 AZ Amsterdam, Netherlands
关键词
Digital radiography; Computed radiography; Image quality; Radiation exposure; Dose indicator; FLAT-PANEL-DETECTOR; X-RAY-SPECTRUM; CHEST RADIOGRAPHY; COMPUTED RADIOGRAPHY; CESIUM IODIDE; MANAGEMENT; OPTIMIZATION; SCREEN; FILM;
D O I
10.1016/j.ejrad.2009.05.060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although the transition from conventional screen-film imaging to digital image acquisition has been almost completed during the last couple of years, examination parameters, such as tube voltage, tube current, and filtration have been adopted from screen-film technology without further adjustments. Digital systems, however, are characterised by their flexibility: the acquisition dose can be reduced at the expense of image quality and vice versa. The imaging parameters must be optimised according to the best performance of a particular system. The traditional means of dose containment, such as positioning and collimation, are as valid for digital techniques as they were for conventional techniques. Digital techniques increasingly offer options for dose reduction. At the same time, there is a risk of substantially increasing the patient dose, possibly unawares, due to the lack of visual control. Therefore, implementation of dose indicators and dose monitoring is mandatory for digital radiography. The use of image quality classes according to the dose requirements of given clinical indications are a further step toward modern radiation protection. (C) 2009 Published by Elsevier Ireland Ltd.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 26 条
[1]  
Burns C, 2004, PEDIATR RADIOL, V34, pS234, DOI 10.1007/s00247-004-1275-8
[2]   Image quality and dose management in digital radiography: A new paradigm for optimisation [J].
Busch, HP ;
Faulkner, K .
RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) :143-147
[3]   Image quality and exposure dose in digital projection radiography [J].
Busch, HP ;
Busch, S ;
Decker, C ;
Schilz, C .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (01) :32-37
[4]   Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector [J].
Dobbins, JT ;
Samei, E ;
Chotas, HG ;
Warp, RJ ;
Baydush, AH ;
Floyd, CE ;
Ravin, CE .
RADIOLOGY, 2003, 226 (01) :221-230
[5]   Optimizing the tube potential for lumbar spine radiography with a flat-pane digital detector [J].
Geijer, H. ;
Norrman, E. ;
Persliden, J. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (973) :62-68
[6]   Reference values for diagnostic radiology: Application and impact [J].
Gray, JE ;
Archer, BR ;
Butler, PF ;
Hobbs, BB ;
Mettler, FA ;
Pizzutiello, RJ ;
Schueler, BA ;
Strauss, KJ ;
Suleiman, OH ;
Yaffe, MJ .
RADIOLOGY, 2005, 235 (02) :354-358
[7]   Contrast-detail phantom study for X-ray spectrum optimization regarding chest radiography using a cesium iodide -: Amorphous silicon flat-panel detector [J].
Hamer, OW ;
Völk, M ;
Zorger, N ;
Borisch, I ;
Büittner, R ;
Feuerbach, S ;
Strotzer, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (10) :610-618
[8]   Investigation of optimum energies for chest imaging using film-screen and computed radiography [J].
Honey, ID ;
MacKenzie, A ;
Evans, DS .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (929) :422-427
[9]   The current concept of speed should not be used to describe digital imaging systems [J].
Huda, W .
RADIOLOGY, 2005, 234 (02) :345-346
[10]  
*ICRP, 1992, ICRP PUBL, V60