Study on the Relationship between Thermal Comfort and Learning Efficiency of Different Classroom-Types in Transitional Seasons in the Hot Summer and Cold Winter Zone of China

被引:11
作者
Liu, Haiqiang [1 ]
Ma, Xidong [2 ]
Zhang, Zhihao [1 ]
Cheng, Xiaoling [1 ]
Chen, Yanmi [3 ]
Kojima, Shoichi [4 ]
机构
[1] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, 928 2nd St, Hangzhou 310018, Peoples R China
[2] Tianjin Univ, Sch Architecture, 92 Weijin Rd, Tianjin 300072, Peoples R China
[3] Zhejiang Sci Tech Univ, Sch Econ & Business Management, 928 2nd St, Hangzhou 310018, Peoples R China
[4] Saga Univ, Grad Sch Sci & Engn, Dept Civil Engn & Architecture, Saga 8408502, Japan
关键词
learning efficiency; thermal comfort; natural environment of different classroom-types; influence relationship; INDOOR ENVIRONMENT QUALITY; PERCEPTION; MODEL; HEAT;
D O I
10.3390/en14196338
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The physical environment of classrooms has a strong relationship with student learning performance and health. Since the outbreak of COVID-19 in 2019, almost all universities have begun implementing closed instructional management, which has forced students to spend a much longer amount of time inside the classroom. This has also led to an increasing problem of thermal comfort in classroom indoor environments. In this paper, classrooms evolved from three dominant teaching modes at Zhejiang Sci-Tech University (ZSTU), located in the Hot Summer and Cold Winter (HSCW) zone of China, were selected as experimental spaces. Meanwhile, 12 learning groups with 60 students (30 of each sex) were selected as the tested samples. The relationship between thermal comfort and learning efficiency of the tested students was established through thermal comfort questionnaires and learning efficiency tests under the typical natural conditions in transition seasons. Based on this, improvement strategies were proposed for the current state of the classroom environment, providing a database for optimizing the environmental conditions of university classrooms in HSCW zone on the basis of improving students' learning efficiency.
引用
收藏
页数:30
相关论文
共 54 条
  • [1] [Anonymous], 2005, GB503522005
  • [2] [Anonymous], 2006, NEUROPSYCHOLOGICAL A
  • [3] [Anonymous], 2005, 77302005 ISO BRIT ST
  • [4] [Anonymous], 2010, GB77932010
  • [5] ASHRAE, 2017, 552017 ASHRAE
  • [6] On the interaction between lighting and thermal comfort: An integrated approach to IEQ
    Bellia, Laura
    Alfano, Francesca Romana d'Ambrosio
    Fragliasso, Francesca
    Palella, Boris Igor
    Riccio, Giuseppe
    [J]. ENERGY AND BUILDINGS, 2021, 231 (231)
  • [7] HEATING AND COOLING STIMULATIONS DURING SWS AND REM-SLEEP IN MAN
    CANDAS, V
    LIBERT, JP
    MUZET, A
    [J]. JOURNAL OF THERMAL BIOLOGY, 1982, 7 (03) : 155 - 158
  • [8] CEN, 2019, EN 16798-2
  • [9] CEN, 2019, 167981 CEN
  • [10] Chen F., 2019, RES ED DEV, V39, P79