Human response to personalized ventilation and mixing ventilation

被引:151
作者
Kaczmarczyk, J [1 ]
Melikov, A [1 ]
Fanger, PO [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Lyngby, Denmark
关键词
individual control; personalized ventilation; office; perceived air quality; SBS symptoms; thermal comfort;
D O I
10.1111/j.1600-0668.2004.00300.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The response of 60 human subjects to a personalized ventilation system (PVS), providing control of positioning of the air terminal device and the airflow rate, was compared with the response to mixing ventilation (MV). Perceived air quality, thermal comfort, intensity of Sick Building Syndrome symptoms and performance of subjects were studied during 3 h 45 min exposures. In case of MV alone the room air temperature was 23degreesC and 26degreesC. The PVS supplied outdoor air at 23degreesC or 20degreesC or recirculated room air at 23degreesC when the room temperature was 23degreesC, and outdoor air at 20degreesC when the room temperature was 26degreesC. The PVS providing outdoor air improved perceived air quality and decreased SBS symptoms compared to MV alone and when the room air was re-circulated through the PVS. The percentage dissatisfied with air quality, 3 min after initial occupancy, decreased from 22% with MV to 7% with PVS; and from 49% to 20%, at room temperatures 23degreesC and 26degreesC, respectively. Over time, these differences in percentage dissatisfied decreased markedly. Headache and decreased ability to think clearly were reported as least intense when the PVS supplied outdoor air at 20degreesC, while the most intense symptoms occurred with MV. PVS increased self-estimated performance.
引用
收藏
页码:17 / 29
页数:13
相关论文
共 23 条
  • [1] [Anonymous], P ROOMV COP DENM
  • [2] [Anonymous], ASHVE T
  • [3] [Anonymous], P ROOMV 2002 COP TEC
  • [4] [Anonymous], 1993, 7730 ISO
  • [5] ASHRAE, 2017, ASHRAE Handbook of Fundamentals
  • [6] *ASHRAE, 1992, 551992 ASHRAE
  • [7] BAKOBIRO Z, 2002, P IND AIR 2002 MONT, V2, P249, DOI [10.1111/j.1600-0668.2004.00218.x, DOI 10.1111/J.1600-0668.2004.00218.X]
  • [8] BAUMAN FS, 1998, ASHRAE T, V104, P1153, DOI DOI 10.1016/J.ENBUILD.2013.06.009
  • [9] *CEN, 1998, 1752 CR CEN EUR COMM
  • [10] Impact of temperature and humidity on perception of indoor air quality during immediate and longer whole-body exposures
    Fang, L
    Clausen, G
    Fanger, PO
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (04): : 276 - 284