This paper deals with the numerical investigation aimed to study the axial capacity and the nonlinear deformation response of pin ended cold-formed steel (CFS) built-up columns under monotonic axial loading, applied concentrically. The built-up sections were constructed by adequately spaced channel sections in a back-toback configuration, connected through webs by means of connecting elements (CFS channels) called spacers. Self-driving screws were used as fasteners to assemble together the lipped channels and spacers. Finite element (FE) models were established and verified against the previously published built-up columns with similar configuration. An extensive parametric study was conducted by varying the key parameters like plate slenderness of the lipped channels, unbraced chord slenderness, and global slenderness in order to investigate their variation on the ultimate compression resistance of these built-up columns. The effective width method was used to determine the design strengths for these built-up columns using the AS/NZ Specifications and European Specification on cold-formed steel structures, which were later compared with the results obtained from the numerical parametric study. This study indicated that the provisions that are given in the current AS/NZS and European Specification in predicting the strengths of the built-up column with spacers had shortcomings. Therefore, new design equations for the reliable design strength predictions of the CFS built-up column composed of lipped channels with spacers were proposed. The incorporation of spacers curtailed the local buckling half-wave length, which improved the buckling resistance, predominantly in the columns failing by local buckling.
引用
收藏
页数:13
相关论文
共 44 条
[1]  
AISI, 1996, S100 AISI
[2]   Improved design procedure for battened cold-formed steel built-up columns composed of lipped angles [J].
Anbarasu, M. ;
Dar, M. Adil .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 164
[3]   Behaviour of cold-formed steel built-up battened columns composed of four lipped angles: Tests and numerical validation [J].
Anbarasu, M. .
ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (01) :51-64
[4]   Behaviour of cold-formed steel built-up I-section columns composed of four U-profiles [J].
Anbarasu, M. ;
Venkatesan, M. .
ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (03) :613-625
[5]   Behaviour and design of cold-formed lean duplex stainless steel lipped channel columns [J].
Anbarasu, M. ;
Ashraf, M. .
THIN-WALLED STRUCTURES, 2016, 104 :106-115
[6]   Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns [J].
Anbarasu, M. ;
Kanagarasu, K. ;
Sukumar, S. .
MATERIALS AND STRUCTURES, 2015, 48 (12) :4029-4038
[7]  
[Anonymous], THESIS
[8]  
[Anonymous], EN199315 BS BRIT STA
[9]  
[Anonymous], J STRUCT DIV ASCE
[10]  
[Anonymous], ABAQUS US MAN VERS 6