Adaptive Safety Early Warning Device for Non-contact Measurement of HVDC Electric Field

被引:11
|
作者
Suo, Chunguang [1 ]
Sun, Hao [1 ]
Zhang, Wenbin [2 ]
Zhou, Nianrong [3 ]
Chen, Weiren [2 ]
机构
[1] Kunming Univ Sci, Coll Sci, Kunming 650500, Yunnan, Peoples R China
[2] Kunming Univ Sci, Coll Mech & Elect Engn, Kunming 650504, Yunnan, Peoples R China
[3] Yunnan Power Grid Co Ltd, Elect Power Res Inst, Kunming 650011, Yunnan, Peoples R China
关键词
non-contact measurement; electric field measurement sensor; adaptive adjustment; voltage level identification; security warning;
D O I
10.3390/electronics9020329
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to prevent electric shock accidents during the maintenance and repair of high-voltage direct current (DC) live equipment, an intelligent safety early warning system device based on non-contact electric field measurement is developed in this paper, to ensure the life safety of electrical workers and the stable operation of equipment. Firstly, the self-developed electric field sensor is used to measure the electric field strength of the space around the charged device. The STM32 microprocessor in the sensor will compare the measured electric field value with a preset safety threshold. If the safety threshold is exceeded, the early warning device issues an audible alarm. It prompts the electric power operator to exit to a safe distance. In addition, the alarm prompt symbol and the real-time waveform of the measured electric field can be seen intuitively on the mobile smart APP interface. Secondly, for devices with different voltage levels, the sensor electric field measurement range and sensitivity can be dynamically adjusted by changing the motor speed. In addition, according to the voltage level identification algorithm, this is also to achieve an adaptive safety early warning of different live equipment. Finally, field experiments were performed at a +/- 500 kV DC converter station and an +/- 800 kV DC transmission line experimental platform. The measured values of the electric field are basically consistent with the simulated values, and the safety early warning device has no false positives or false negatives during the test. The experimental results show that the design of the safety warning device in this paper meets the actual needs, and it can alert the electric workers to the specified safety distance.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Research on the non-contact early warning of dangerous electric field by overhead transmission lines
    Zhang, Wenbin
    Zhou, Nianrong
    Tang, Lijun
    Qi, Fagui
    Zhao, Lei
    INTEGRATED FERROELECTRICS, 2017, 181 (01) : 141 - 150
  • [2] Research and Experiment on Field Warning Device of Non-contact Type
    Li, Songnong
    Zhou, Qiang
    Hou, Xingzhe
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, CHEMISTRY AND COMPUTER ENGINEERING 2015 (ICMMCCE 2015), 2015, 39 : 2855 - 2860
  • [3] NON-CONTACT LASER MEASUREMENT DEVICE
    Vlk, Lukas
    XXIV. MEDZINARODNA KONFERENCIA SUCASNE PROBLEMY V KOLAJAVYCH VOZIDLACH, DIEL II, 2019, : 329 - 336
  • [4] Non-Contact Early Warning of Shaking Palsy
    Yan, Xiaodong
    Fan, Dou
    Ren, Aifeng
    Zhao, Nan
    Zhang, Zhiya
    Haider, Daniyal
    Khan, Muhammad Bilal
    Tian, Jie
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2019, 7
  • [5] Non-contact Voltage Measurement Based on Electric-Field Effect
    Wei, Shaoliang
    Zhang, Licheng
    Gao, Wenchang
    Cao, Zhongyue
    CEIS 2011, 2011, 15
  • [6] Non-Contact Adaptive Voltage Sensor Based on Electric Field Coupling Principle
    Tan, Xiangyu
    Zhang, Wenbin
    He, Mingxing
    Li, Wenyun
    Ao, Gang
    Zhou, Fangrong
    SENSORS, 2023, 23 (19)
  • [7] Non-contact measurement of the electric field shielding performance and the resistivity of layer materials
    Chubb, J. N.
    JOURNAL OF ELECTROSTATICS, 2006, 64 (10) : 685 - 689
  • [8] Non-Contact Measurement Device based on Ultrasonic Technology
    Lan, Zhenping
    Meng, Huimin
    Li, Jintao
    Wang, Yuru
    Li, Ping
    Jin, Jiyu
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 2654 - 2657
  • [9] Non-Contact Measurement of Electric Potential of PV Modules
    Hishikawa, Yoshihiro
    Yamagoe, Kengo
    Onuma, T.
    2015 IEEE 42ND PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2015,
  • [10] The Research on he Optimized Non-Contact Electric-Field Measurement Method of Electric-Field for Detecting Insulators
    Zhang, Zhanlong
    Huang, Danmei
    Wu, Xihong
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1752 - +