Electrosynthesis and permselective characterisation of phenol-based polymers for biosensor applications

被引:20
作者
Craig, JD [1 ]
O'Neill, RD [1 ]
机构
[1] Natl Univ Ireland Univ Coll Dublin, Dept Chem, Dublin 4, Ireland
关键词
polymer-modified Pt electrode; glucose oxidase; ascorbic acid interference; hydrogen peroxide; amperometry; electrochemical quartz crystal microbalance polyphenol; catechol; 2-methylphenol; 2-hydroxyphenylacetic acid; 2-ethylphenol; 2,6-dichlorophenol; 2.6-difluorophenot; 2.6-dimethylphenol;
D O I
10.1016/j.aca.2003.08.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A range of mono- and di-substituted phenol monomers were investigated as candidates for the generation of electrosynthesised polymers to act as permselective membranes in Pt-based amperometric biosensors. Two analytes were used as permeability probes: the enzyme signal transduction molecule in first generation biosensors, H2O2; and the archetypal interference species in biological applications, ascorbic acid (AA). A selectivity parameter, S (%), defined as the ratio of AA to H2O2 responses, was used to rank the polymers. Two previously reported electrodes were used as benchmarks: bare Pt and Pt modified with a poly (1,2-diaminobenzene)/albumin composite, Pt/PPD-BSA. The AA-blocking characteristics of poly(phenol) were better than the benchmarks, but low H2O2 permeability gave high (poor) S (%) values. In contrast to the effects of proteins on PPD, incorporation of albumin into the poly(phenol) matrix made the polymer more permeable to AA. Modification of the phenol monomer with alkyl substituents also increased the permeability of the resulting polymers to AA. Analogous modifications with halogens significantly improved the AA-rejecting properties of these polymers, with Pt electrodes modified with polymers generated from 2,6-difluorophenol showing four orders of magnitude lower sensitivity to AA compared with bare metal. Electrochemical QCM measurements indicated that poly(phenol) films electrosynthesised on Pt at pH 7.4 were significantly thinner (3 +/- 1 nm) than PPD membranes (20 +/- 3 nm). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 43
页数:11
相关论文
共 51 条
[1]  
[Anonymous], 1997, BIOSENSORS BODY CONT
[2]  
[Anonymous], 1987, Biosensors Fundamentals and Applications
[3]   THEORY OF ULTRAMICROELECTRODES [J].
AOKI, K .
ELECTROANALYSIS, 1993, 5 (08) :627-639
[4]   A scanning force microscopy study of poly(phenol) films containing immobilized glucose oxidase [J].
Arrigan, DWM ;
Bartlett, PN .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :293-304
[5]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[6]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[7]   An enzyme switch employing direct electrochemical communication between horseradish peroxidase and a poly(aniline) film [J].
Bartlett, PN ;
Birkin, PR ;
Wang, JH ;
Palmisano, F ;
De Benedetto, G .
ANALYTICAL CHEMISTRY, 1998, 70 (17) :3685-3694
[8]   Characterization of polyaniline films electrodeposited on mild steel in aqueous p-toluenesulfonic acid solution [J].
Camalet, JL ;
Lacroix, JC ;
Aeiyach, S ;
Lacaze, PC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 445 (1-2) :117-124
[9]  
Cass A. E. G., 1990, BIOSENSORS PRACTICAL
[10]   PERMEATION OF SOLUTES THROUGH AN ELECTROPOLYMERIZED ULTRATHIN POLY-O-PHENYLENEDIAMINE FILM USED AS AN ENZYME-ENTRAPPING MEMBRANE [J].
CENTONZE, D ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
ELECTROANALYSIS, 1994, 6 (5-6) :423-429