Residual solvent;
Process chemistry;
Green chromatography;
High throughput analysis;
Gas chromatography;
Hydrogen;
RESIDUAL SOLVENTS;
D O I:
10.1016/j.jpba.2018.12.006
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Within the pharmaceutical industry, the determination of residual solvents by Gas Chromatography Flame Ionization Detection (GC-FID) is a highly utilized analytical test that often employs helium (He) as the carrier gas. However, many do not realize that helium is a non-renewable resource that will eventually become progressively more difficult to source. In recent years, analytical chemists are increasingly adopting hydrogen (H-2) in place of helium for routine GC analysis. In this study, a simple and efficient generic/universal GC-FID method using H-2 as the carrier gas has been developed with the capability of baseline resolution of over 30 of the most commonly used solvents in development and manufacturing with a method run time of less than eight minutes. The use of this method for the separation and analysis of solvents within a pharmaceutical manufacturing process is demonstrated with additional method validation data presented using five different diluents as a means to increase flexibility for the chromatographer. Furthermore, it is the recommendation of the authors that the current compendia for residual solvent analysis be updated to allow for hydrogen as a carrier gas. The similarity between He and H-2 observed within this study supports the use of hydrogen as a suitable replacement for helium, and an update of the EU and USP compendia for residual solvent analysis should be made to reflect this. (C) 2018 Elsevier B.V. All rights reserved.