A high performance sensor based on PANI/ZnTi-LDHs nanocomposite for trace NH3 detection

被引:37
|
作者
Qin, Yuxiang [1 ,2 ,3 ]
Wang, Liping [1 ,2 ]
Wang, Xiaofei [1 ,2 ]
机构
[1] Tianjin Univ, Sch Microelect, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Tianjin Key Lab Imaging & Sensing Microelect Tech, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Sch Mat Sci & Engn, Key Lab Adv Ceram & Machining Technol, Minist Educ, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Polyaniline; Layered double hydroxides; Nanocomposite; Gas sensor; Ammonia; LAYERED DOUBLE HYDROXIDES; GAS-SENSING PROPERTIES; THIN-FILM; HYBRID; NANOPARTICLES; TEMPERATURE; PANI; DESIGN;
D O I
10.1016/j.orgel.2018.12.018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The organic/inorganic nanocomposites materials have obtained considerable interest in gas sensors field in virtue of synergetic or complementary effects between respective components. In this work, loose three-dimensional (3D) nanocomposite of polyaniline (PANI)/ZnTi layered double hydroxides (ZnTi-LDHs), capable of NH3 sensing with high response and great long-term stability at room temperature, was prepared by entrapping PANI into 3D hierarchical ZnTi-LDHs matrices. The hierarchical ZnTi-LDHs was synthesized by hydrothermal method, and the PANI was entrapped into the ZnTi-LDHs matrices uniformly via in-situ chemical oxidative polymerization. Comparative investigations on the NH3-sensing properties of the single component (PANI, ZnTi-LDHs) and composite of PANI/ZnTi-LDHs demonstrate that the as-prepared PANI/ZnTi-LDHs composite displays about 20 and 2 times enhancement in response value to 50 ppm NH3 at room temperature compared with the single PANI and ZnTi-LDHs, respectively. The composite sensor also exhibits good long-term stability and low limit of detection (200 ppb). Meanwhile, the unique 3D loose architecture of the composite contributes to unique dynamic characteristics of transient response and ultrafast recovery; the response time and recovery time measured are within 3s and 110s respectively. The underlying NH3-sensing mechanism for PANI/ZnTi-LDHs sensor, particularly the notable response enhancement was demonstrated.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 50 条
  • [41] Tailored coral-like polyaniline nanorods for trace detection and self-cleaning NH3 sensor at room temperature
    Xu, Tengfei
    Chen, Qingcai
    Liu, Huan
    Sha, Tong
    Liu, Wenhao
    Cheng, Jingwen
    Hu, Yukun
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2025, 13 (03):
  • [42] Ultrasensitive ammonia (NH3) gas sensor: DFT Simulation-Directed Selection of High-Performance Metal-Doped Molybdenum Tri-oxide (α-MoO3) Nanoribbons for NH3 Detection
    Kwak, Dongwook
    Sokol, Henry
    Moser, Bryan P.
    Ryu, Heejeong
    Koski, Kristie J.
    Maric, Radenka
    Zhang, Liang
    Lei, Yu
    2019 IEEE SENSORS, 2019,
  • [43] Room temperature high performance NH3 sensor based on GO-rambutan-like polyaniline hollow nanosphere hybrid assembled to flexible PET substrate
    Li, Siqi
    Wang, Tianshuang
    Yang, Zijie
    He, Junming
    Wang, Jing
    Zhao, Lianjing
    Lu, Huiying
    Tian, Tian
    Liu, Fangmeng
    Sun, Peng
    Yan, Xu
    Lu, Geyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 726 - 734
  • [44] Sensitivity of ZnO based NH3 Sensor by RF Magnetron Sputtering
    Ahmed, S.
    Sin, N. D. Md
    Berhan, M. N.
    Rusop, M.
    ADVANCED MATERIALS ENGINEERING AND TECHNOLOGY, 2012, 626 : 168 - +
  • [45] A Fast Room Temperature NH3 Sensor Based on an Al/p-Si/Al Structure with Schottky Electrodes
    Zhu, Suwan
    Liu, Xiaolong
    Zhuang, Jun
    Zhao, Li
    SENSORS, 2017, 17 (08):
  • [46] PANI/TiO2 nanocomposite-based chemiresistive gas sensor for the detection of E. Coli bacteria
    Venkatachalaiah, Chaitra
    Venkataraman, Uma
    Sellappan, Raja
    IET NANOBIOTECHNOLOGY, 2020, 14 (09) : 761 - 765
  • [47] Flexible strain sensor with high performance based on PANI/PDMS films
    Gong, Xin Xin
    Fei, Guang Tao
    Fu, Wen Biao
    Fang, Ming
    Gao, Xu Dong
    Zhong, Bin Nian
    Zhang, Li De
    ORGANIC ELECTRONICS, 2017, 47 : 51 - 56
  • [48] Highly sensitive and selective PAni-CeO2 nanohybrid for detection of NH3 biomarker at room temperature
    Dhanawade, Reshma N.
    Pawar, Nanasaheb S.
    Chougule, Manik A.
    Hingangavkar, Gajanan M.
    Jadhav, Yogesh M.
    Nimbalkar, Tanaji M.
    Navale, Yuvraj H.
    Chavan, Ganesh T.
    Jeon, Chan-Wook
    Patil, Vikas B.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2023, 34 (09)
  • [49] MoS2-Based NH3 Sensor for In Situ Helicobacter pylori Detection
    Zhao, Minmin
    Zhang, Zhu
    Tan, Chao
    Wang, Wei
    Yang, Lei
    Wang, Zegao
    ACS APPLIED MATERIALS & INTERFACES, 2024, : 69798 - 69806
  • [50] High-performance room temperature gas sensor based on gold(III) pincer complex with high sensitivity for NH3
    Tabrizi, Leila
    Chiniforoshan, Hossein
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 245 : 815 - 820