Molecular-imprinted, polymer-coated quartz crystal microbalances for the detection of terpenes

被引:100
作者
Percival, CJ [1 ]
Stanley, S
Galle, M
Braithwaite, A
Newton, MI
McHale, G
Hayes, W
机构
[1] Nottingham Trent Univ, Dept Chem & Phys, Nottingham NG11 8NS, England
[2] Univ Reading, Dept Chem, Reading RG6 6AD, Berks, England
关键词
D O I
10.1021/ac0155198
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A piezoelectric sensor coated with an artificial biomimetic recognition element has been developed for the determination of L-menthol in the liquid phase. A highly specific noncovalently imprinted polymer (MIP) was cast in situ on to the surface of a gold-coated quartz crystal microbalance (QCM) electrode as a thin permeable film. Selective rebinding of the target analyte was observed as a frequency shift quantified by piezoelectric microgravimetry with the QCM. The detectability of L-menthol was 200 ppb with a response range of 0-1.0 ppm. The response of the MIP-QCM to a range of monoterpenes was investigated with the sensor binding menthol in favor of analogous compounds. The sensor was able to distinguish between the D- and L-enantiomers of menthol owing to the enantioselectivity of the imprinted sites. To our knowledge, this is the first report describing enantiomeric resolution within an MIP utilizing a single monomer-functional moiety interaction. It is envisaged that this technique could be employed to determine the concentration of terpenes in the atmosphere.
引用
收藏
页码:4225 / 4228
页数:4
相关论文
共 30 条
[1]   Trace organic compounds in landfill gas at seven UK waste disposal sites [J].
Allen, MR ;
Braithwaite, A ;
Hills, CC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (04) :1054-1061
[2]   MOLECULAR RECOGNITION IN SYNTHETIC-POLYMERS - PREPARATION OF CHIRAL STATIONARY PHASES BY MOLECULAR IMPRINTING OF AMINO-ACID AMIDES [J].
ANDERSSON, LI ;
OSHANNESSY, DJ ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 513 :167-179
[3]   ENANTIOMERIC RESOLUTION ON MOLECULARLY IMPRINTED POLYMERS PREPARED WITH ONLY NONCOVALENT AND NONIONIC INTERACTIONS [J].
ANDERSSON, LI ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (02) :313-322
[4]   DUAL QUARTZ-CRYSTAL MICROBALANCE OSCILLATOR CIRCUIT - MINIMIZING EFFECTS DUE TO LIQUID VISCOSITY, DENSITY, AND TEMPERATURE [J].
BRUCKENSTEIN, S ;
MICHALSKI, M ;
FENSORE, A ;
LI, ZF ;
HILLMAN, AR .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1847-1852
[5]   Molecularly imprinted sensor layers for the detection of polycyclic aromatic hydrocarbons in water [J].
Dickert, FL ;
Tortschanoff, M ;
Bulst, WE ;
Fischerauer, G .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4559-4563
[6]   Molecular imprinting in chemical sensing [J].
Dickert, FL ;
Hayden, O .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :192-199
[7]   USE OF SILANE MONOMERS FOR MOLECULAR IMPRINTING AND ENZYME ENTRAPMENT IN POLYSILOXANE-COATED POROUS SILICA [J].
GLAD, M ;
NORRLOW, O ;
SELLERGREN, B ;
SIEGBAHN, N ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (01) :11-23
[8]   Acoustic wave microsensor arrays for vapor sensing [J].
Grate, JW .
CHEMICAL REVIEWS, 2000, 100 (07) :2627-2647
[9]   Discrimination between enantiomers of structurally related molecules: Separation of benzodiazepines by molecularly imprinted polymers [J].
Hart, BR ;
Rush, DJ ;
Shea, KJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (03) :460-465
[10]   Imprinted polymer-based enantioselective acoustic sensor using a quartz crystal microbalance [J].
Haupt, K ;
Noworyta, K ;
Kutner, W .
ANALYTICAL COMMUNICATIONS, 1999, 36 (11-12) :391-393