Direct electron transfer and enzymatic activity of hemoglobin in a hexagonal mesoporous silica matrix

被引:258
作者
Dai, ZH [1 ]
Liu, SQ [1 ]
Ju, HX [1 ]
Chen, HY [1 ]
机构
[1] Nanjing Univ, Dept Chem, Inst Analyt Sci, State Key Lab Coordinat Chem, Nanjing 210093, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
biosensors; hemoglobin; hexagonal mesoporous silica; glassy carbon electrode; direct electron transfer; hydrogen peroxide; nitrate;
D O I
10.1016/j.bios.2003.08.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The direct electrochemistry of hemoglobin (Hb) immobilized on a hexagonal mesoporous silica (HMS)-modified glassy carbon electrode was described. The interaction between Hb and the HMS was investigated using UV-Vis spectroscopy, FT-IR, and electrochemical methods. The direct electron transfer of the immobilized Hb exhibited two couples of redox peaks with the formal potentials of -0.037 and -0,232 V in 0.1 M (pH 7.0) PBS, respectively, which corresponded to its two immobilized states. The electrode reactions showed a surface-controlled process with a single proton transfer at the scan rate range from 20 to 200 mV/s. The immobilized Hb retained its biological activity well and displayed an excellent response to the reduction of both hydrogen peroxide (H2O2) and nitrate (NO2-). Its apparent Michaelis-Menten constants for H2O2 and NO2- were 12.3 and 49.3 muM, respectively, showing a good affinity. Based on the immobilization of Hb on the HMS and its direct electrochemistry, two novel biosensors for H2O2 and NO2- were presented. Under optimal conditions, the sensors could be used for the determination of H2O2 ranging from 0.4 to 6.0 muM and NO2- ranging from 0.2 to 3.8 muM. The detection limits were 1.86 x 10(-9) M and 6.11 X 10(-7) M at 3sigma, respectively. HMS provided a good matrix for protein immobilization and biosensor preparation. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:861 / 867
页数:7
相关论文
共 48 条
[21]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[22]  
Lei CH, 1999, ELECTROANAL, V11, P274, DOI 10.1002/(SICI)1521-4109(199904)11:4<274::AID-ELAN274>3.0.CO
[23]  
2-G
[24]   Hydrogen peroxide sensor based on coimmobilized methylene green and horseradish peroxidase in the same montmorillonite-modified bovine serum albumin-glutaraldehyde matrix on a glassy carbon electrode surface [J].
Lei, CH ;
Deng, JQ .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3344-3349
[25]   A reagentless amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene green in a modified zeolite matrix [J].
Liu, BH ;
Yan, F ;
Kong, JL ;
Deng, JQ .
ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) :31-39
[26]   Characterization of immobilization of an enzyme in a modified Y zeolite to matrix and its application to an amperometric glucose biosensor [J].
Liu, BH ;
Hu, RQ ;
Deng, JQ .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2343-2348
[27]  
LU Z, 1990, ELECTROCHIM ACTA, V35, P1139
[28]   Photocontrolled reversible release of guest molecules from coumarin-modified mesoporous silica [J].
Mal, NK ;
Fujiwara, M ;
Tanaka, Y .
NATURE, 2003, 421 (6921) :350-353
[29]  
MURRAY RW, 1984, ELECTROANAL CHEM, V13, P191
[30]   ELECTRON-TRANSFER FROM ELECTRODES TO MYOGLOBIN - FACILITATED IN SURFACTANT FILMS AND BLOCKED BY ADSORBED BIOMACROMOLECULES [J].
NASSAR, AEF ;
WILLIS, WS ;
RUSLING, JF .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2386-2392