Low-dimensional-Structure Self-Learning and Thresholding: Regularization Beyond Compressed Sensing for MRI Reconstruction

被引:112
作者
Akcakaya, Mehmet [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Goddu, Beth [1 ,2 ]
Goepfert, Lois A. [1 ,2 ]
Kissinger, Kraig V. [1 ,2 ]
Tarokh, Vahid [4 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[4] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
关键词
compressed sensing; accelerated imaging; image reconstruction; block matching; learning algorithm; cardiac MR; coronary MRI; SPARSE; RESOLUTION;
D O I
10.1002/mrm.22841
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An improved image reconstruction method from undersampled k-space data, low-dimensional-structure self-learning and thresholding (LOST), which utilizes the structure from the underlying image is presented. A low-resolution image from the fully sampled k-space center is reconstructed to learn image patches of similar anatomical characteristics. These patches are arranged into 'similarity clusters,' which are subsequently processed for dealiasing and artifact removal, using underlying low-dimensional properties. The efficacy of the proposed method in scan time reduction was assessed in a pilot coronary MRI study. Initially, in a retrospective study on 10 healthy adult subjects, we evaluated retrospective undersampling and reconstruction using LOST, wavelet-based I-1-norm minimization, and total variation compressed sensing. Quantitative measures of vessel sharpness and mean square error, and qualitative image scores were used to compare reconstruction for rates of 2,3, and 4. Subsequently, in a prospective study, coronary MRI data were acquired using these rates, and LOST-reconstructed images were compared with an accelerated data acquisition using uniform undersampling and sensitivity encoding reconstruction. Subjective image quality and sharpness data indicate that LOST outperforms the alternative techniques for all rates. The prospective LOST yields images with superior quality compared with sensitivity encoding or I-1-minimization compressed sensing. The proposed LOST technique greatly improves image reconstruction for accelerated coronary MRI acquisitions. Magn Reson Med 66:756-767,2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:756 / 767
页数:12
相关论文
共 42 条
[21]   SPIRiT: Iterative Self-consistent Parallel Imaging Reconstruction From Arbitrary k-Space [J].
Lustig, Michael ;
Pauly, John M. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) :457-471
[22]   QUANTITATIVE-EVALUATION OF SEVERAL PARTIAL FOURIER RECONSTRUCTION ALGORITHMS USED IN MRI [J].
MCGIBNEY, G ;
SMITH, MR ;
NICHOLS, ST ;
CRAWLEY, A .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) :51-59
[23]   FAST SPIRAL CORONARY-ARTERY IMAGING [J].
MEYER, CH ;
HU, BS ;
NISHIMURA, DG ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :202-213
[24]   Highly constrained backprojection for time-resolved MRI [J].
Mistretta, CA ;
Wieben, O ;
Velikina, J ;
Block, W ;
Perry, J ;
Wu, Y ;
Johnson, K ;
Wu, Y .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :30-40
[25]   Model-Based Reconstruction for Cardiac Cine MRI Without ECG or Breath Holding [J].
Odille, Freddy ;
Uribe, Sergio ;
Batchelor, Philip G. ;
Prieto, Claudia ;
Schaeffter, Tobias ;
Atkinson, David .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) :1247-1257
[26]  
Otazo R., 2010, Proc. of the 18th Sci. Meeting ofISMRM, P4867
[27]   Combination of Compressed Sensing and Parallel Imaging for Highly Accelerated First-Pass Cardiac Perfusion MRI [J].
Otazo, Ricardo ;
Kim, Daniel ;
Axel, Leon ;
Sodickson, Daniel K. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) :767-776
[28]  
Peters DC, 2000, MAGNET RESON MED, V43, P91, DOI 10.1002/(SICI)1522-2594(200001)43:1<91::AID-MRM11>3.0.CO
[29]  
2-4
[30]   Mutual-information-based registration of medical images: A survey [J].
Pluim, JPW ;
Maintz, JBA ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) :986-1004