Characteristics of peripheral microembolization during iliac stenting: Doppler ultrasound monitoring

被引:15
作者
Kudo, T [1 ]
Inoue, Y [1 ]
Nakamura, H [1 ]
Sugano, N [1 ]
Hirokawa, M [1 ]
Iwai, T [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Dept Vasc & Appl Surg, Bunkyo Ku, Tokyo 1138519, Japan
关键词
microembolization; iliac artery; stent; angioplasty; Doppler ultrasound;
D O I
10.1016/j.ejvs.2005.04.004
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective. To evaluate the characteristics of distal microembolic signals (MES) during iliac stenting using Doppler ultrasound monitoring. Design. Prospective clinical study. Methods. A 2-MHz probe was used to monitor continuously at the ipsilateral tibioperoneal trunks during technically and hemodynamically successful iliac stenting in 10 patients without infrainguinal occlusive lesion. MESs at guide-wire, balloon, or stent crossing (phase 1), predilatation (phase 2), stent deployment (phase 3), postdilatation (phase 4), and contrast medium or heparinized saline injection (at injection) were analyzed. Differentiation of gaseous emboli from particulate emboli was achieved by calculation of the sample volume length. Results. No distal embolic complications were observed. Five hundred and forty-one MESs were detected. The MES incidence and intensity in phase 3 were significantly higher than those in phase 1, phase 2, and phase 4 (p < 0.05). The MES intensity at injection was significantly higher than that in each of four phases (p < 0.0001). Conclusions. Both the MES incidence and intensity were highest at stent deployment. Further study is required of microembolism during endovascular procedures in the lower extremities.
引用
收藏
页码:311 / 314
页数:4
相关论文
共 15 条
[1]   Detection of distal emboli in patients with peripheral arterial stenosis before and after iliac angioplasty: A prospective study [J].
Al-Hamali, S ;
Baskerville, P ;
Fraser, S ;
Walters, H ;
Markus, HS .
JOURNAL OF VASCULAR SURGERY, 1999, 29 (02) :345-351
[2]   Effect of the distal-balloon protection system on microembolization during carotid stenting [J].
Al-Mubarak, N ;
Roubin, GS ;
Vitek, JJ ;
Iyer, SS ;
New, G ;
Leon, MB .
CIRCULATION, 2001, 104 (17) :1999-2002
[3]   THE COMPLICATION RATE OF PERCUTANEOUS PERIPHERAL BALLOON ANGIOPLASTY [J].
BELLI, AM ;
CUMBERLAND, DC ;
KNOX, AM ;
PROCTER, AE ;
WELSH, CL .
CLINICAL RADIOLOGY, 1990, 41 (06) :380-383
[4]  
Benichou H, 1996, J ENDOVASC SURG, V3, P217, DOI 10.1583/1074-6218(1996)003<0217:CAASWP>2.0.CO
[5]  
2
[6]   Solid or gaseous circulating brain emboli: Are they separable by transcranial ultrasound? [J].
Darbellay, GA ;
Duff, R ;
Vesin, JM ;
Despland, PA ;
Droste, DW ;
Molina, L ;
Serena, J ;
Sztajzel, R ;
Ruchat, P ;
Karapanayiotides, T ;
Kalangos, A ;
Bogousslavsky, J ;
Ringelstein, EB ;
Devuyst, G .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2004, 24 (08) :860-868
[7]  
GAINES PA, 1988, LANCET, V1, P168
[8]   Doppler ultrasound monitoring for detection of microembolic signals in peripheral arteries [J].
Kudo, T ;
Inoue, Y ;
Sugano, N ;
Iwai, T .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2002, 24 (01) :37-42
[9]   Stent placement versus percutaneous transluminal angioplasty of human carotid arteries in cadavers in situ:: Distal embolization and findings at intravascular US, MR imaging, and histopathologic analysis' [J].
Manninen, HI ;
Räsänen, HT ;
Vanninen, RL ;
Vainio, P ;
Hippeläinen, M ;
Kosma, VM .
RADIOLOGY, 1999, 212 (02) :483-492
[10]   PULSE DOPPLER ULTRASOUND DETECTION, CHARACTERIZATION AND SIZE ESTIMATION OF EMBOLI IN FLOWING BLOOD [J].
MOEHRING, MA ;
KLEPPER, JR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (01) :35-44