Capsule Deformation in Pharmaceutical Industry by a Non-Contact Metrology Algorithm

被引:0
作者
Khan, Sadaf Jamil [1 ]
Sharif, Muhammad [1 ]
Raza, Mudassar [1 ]
Yasmin, Mussarat [1 ]
Shah, Jamal Hussain [1 ]
机构
[1] COMSATS Inst Informat Technol, Dept Comp Sci, Islamabad 47040, Pakistan
关键词
Non-Contact Metrology; Capsule Deformation; Segmentation; Adaptive Smoothing; Spatial Energy Filters; Gaussian Filter; TRIANGULATION; CALIBRATION; PROBE;
D O I
10.1166/jmihi.2015.1377
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Metrology is the science and art of precision measurement, testing and evaluation. It has a vital role in technological development. In this paper, a Non-contact metrology based new technique is proposed to automatically distinguish the qualified and unqualified capsules manufactured in the pharmaceutical industry based on image processing technique. The existing algorithms for the same purpose are work on the principle of pixel to pixel comparison with a fixed window size of neighborhood. When the image is scaled or translated, the pixel to pixel comparison is difficult to achieve. A small effort is, therefore, made to solve this problem using a new technique for automatic window size determination. Gaussian filter is applied for smoothing and non-linear filter is applied for re-smoothing as a preprocessing step. In addition, edges are detected by canny edge detector and Gabor energy filters. Results obtained reveal that the proposed technique for automatic window size determination is a good and efficient solution with the use of Hausdroff distance, through which a binary comparison is performed after segmentation and thresholding.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
[21]   Feasibility Study of A Non-Contact AC Voltage Measurement System [J].
Shenil, P. S. ;
Arjun, R. ;
George, Boby .
2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, :399-404
[22]   A Systematic Overview of Recent Methods for Non-Contact Chronic Wound Analysis [J].
Marijanovic, Domagoj ;
Filko, Damir .
APPLIED SCIENCES-BASEL, 2020, 10 (21) :1-28
[23]   Implementation of Thermal Camera for Non-Contact Physiological Measurement: A Systematic Review [J].
Manullang, Martin Clinton Tosima ;
Lin, Yuan-Hsiang ;
Lai, Sheng-Jie ;
Chou, Nai-Kuan .
SENSORS, 2021, 21 (23)
[24]   Non-contact temperature measurement at the Physikalisch-Technische Bundesanstalt (PTB) [J].
Mueller, I. ;
Adibekyan, A. ;
Anhalt, K. ;
Baltruschat, C. ;
Gutschwager, B. ;
Koenig, S. ;
Kononogova, E. ;
Monte, C. ;
Reiniger, M. ;
Schiller, S. ;
Taubert, D. R. ;
Urban, D. ;
Hollandt, J. .
QUANTITATIVE INFRARED THERMOGRAPHY JOURNAL, 2021, 18 (03) :187-212
[25]   A non-contact measurement method for rock mass discontinuity orientations by smartphone [J].
Chen, Kejing ;
Jiang, Qinghui .
JOURNAL OF ROCK MECHANICS AND GEOTECHNICAL ENGINEERING, 2023, 15 (11) :2892-2900
[26]   Non-contact Raman spectroscopy using the Y-shaped probes [J].
A. P. Goncharov ;
V. S. Gorelik .
Bulletin of the Lebedev Physics Institute, 2010, 37 :157-158
[27]   Orientation error compensation of turntable for calibration of a non-contact measurement system [J].
Huo, Ju ;
Zhong, Xiao-Qing ;
Yang, Ming ;
Liu, Jia .
Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (01) :100-105
[28]   A Non-Contact Measurement of Animal Body Size Based on Structured Light [J].
Xu, Fangzhou ;
Zhang, Yuxuan ;
Zhang, Zelin ;
Geng, Nan .
APPLIED SCIENCES-BASEL, 2024, 14 (02)
[29]   Non-contact Raman spectroscopy using the Y-shaped probes [J].
Goncharov, A. P. ;
Gorelik, V. S. .
BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2010, 37 (05) :157-158
[30]   An Auto-Balancing Scheme for Non-Contact AC Voltage Measurement [J].
Shenil, P. S. ;
George, Boby .
2018 IEEE 9TH INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2018, :189-193