In this work, the effect of the size and geometrical shape of coating defects on pipeline corrosion under alternating current (AC) interference in a deoxygenated, near-neutral pH bicarbonate solution was studied by direct current (DC) potential analysis, polarization curve measurements, and surface characterization. The results demonstrate that the size of the defect is critical to AC corrosion of steel occurring at the defect base. When a defect is small, the threshold AC to induce pitting corrosion is low. Moreover, both anodic and cathodic current densities decrease, which is attributed to the blocking effect of corrosion product accumulating at the defect. The shape of the defect affects corrosion only when the defect is small, e.g., 5 mm in diameter. The effect becomes undetectable when the defect is large, e.g., 10 mm in diameter. Generally, circular and triangular defects are associated with the most and least negative DC potentials as well as the largest and smallest anodic current densities, respectively, while square-shaped defects fell somewhere in between in terms of both potential density and current density values.
引用
收藏
页码:267 / 276
页数:10
相关论文
共 24 条
[1]  
Blog CP, 2013, MP, V52, P38
[2]  
Bortels L., 2010, MAT PERF, V49, P2
[3]   A theoretical study of AC-induced corrosion considering diffusion phenomena [J].
Bosch, RW ;
Bogaerts, WF .
CORROSION SCIENCE, 1998, 40 (2-3) :323-336
[4]   Investigation of Alternating Current Corrosion of Cathodically Protected Pipelines: Development of a Detection Method, Mitigation Measures, and a Model for the Mechanism [J].
Buechler, M. ;
Schoeneich, H. -G. .
CORROSION, 2009, 65 (09) :578-586
[5]   Life prediction estimation of an underground pipeline using alternate current impedance and reliability analysis [J].
Castaneda, H ;
Alamilla, J ;
Perez, R .
CORROSION, 2004, 60 (05) :429-436
[6]   Corrosion due to AC influence of very high voltage power lines on polyethylene-coated steel pipelines: evaluation of risks - preventive measures [J].
Collet, E ;
Delores, B ;
Gabillard, M ;
Ragault, I .
ANTI-CORROSION METHODS AND MATERIALS, 2001, 48 (04) :221-226
[7]   Localized EIS characterization of corrosion of steel at coating defect under cathodic protection [J].
Dong, C. F. ;
Fu, A. Q. ;
Li, X. G. ;
Cheng, Y. F. .
ELECTROCHIMICA ACTA, 2008, 54 (02) :628-633
[8]   Effect of alternating current on corrosion and effectiveness of cathodic protection of pipelines [J].
Fu, A. Q. ;
Cheng, Y. F. .
CANADIAN METALLURGICAL QUARTERLY, 2012, 51 (01) :81-90
[9]   AC corrosion. Part 2: Parameters influencing corrosion rate [J].
Goidanich, Sara ;
Lazzari, Luciano ;
Ormellese, Marco .
CORROSION SCIENCE, 2010, 52 (03) :916-922
[10]   AC corrosion - Part 1: Effects on overpotentials of anodic and cathodic processes [J].
Goidanich, Sara ;
Lazzari, Luciano ;
Ormellese, Marco .
CORROSION SCIENCE, 2010, 52 (02) :491-497