Collapse simulations of a long span transmission tower-line system subjected to near-fault ground motions

被引:34
|
作者
Tian, Li [1 ]
Pan, Haiyang [1 ]
Ma, Ruisheng [1 ,2 ]
Qiu, Canxing [1 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
[2] Curtin Univ, Sch Civil & Mech Engn, Ctr Infrastruct Monitoring & Protect, Kent St, Bentley, WA 6102, Australia
基金
中国国家自然科学基金;
关键词
long span transmission tower-line system; collapse simulation; near-fault ground motion; collapse fragility; collapse mechanism; RESPONSES;
D O I
10.12989/eas.2017.13.2.211
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Observations from past strong earthquakes revealed that near-fault ground motions could lead to the failure, or even collapse of electricity transmission towers which are vital components of an overhead electric power delivery system. For assessing the performance and robustness, a high-fidelity three-dimension finite element model of a long span transmission tower-line system is established with the consideration of geometric nonlinearity and material nonlinearity. In the numerical model, the Tian-Ma-Qu material model is utilized to capture the nonlinear behaviours of structural members, and the cumulative damage D is defined as an index to identify the failure of members. Consequently, incremental dynamic analyses (IDAs) are conducted to study the collapse fragility, damage positions, collapse margin ratio (CMR) and dynamic robustness of the transmission towers by using twenty near-fault ground motions selected from PEER. Based on the bending and shear deformation of structures, the collapse mechanism of electricity transmission towers subjected to Chi-Chi earthquake is investigated. This research can serve as a reference for the performance of large span transmission tower line system subjected to near-fault ground motions.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 50 条
  • [1] Seismic response of large crossing transmission tower-line system subjected to near-fault ground motions
    School of Civil Engineering, Harbin Institute of Technology, Heilongjiang 150090, China
    不详
    Gongcheng Lixue, 6 (77-82+106):
  • [2] Shaking Table Tests of a Reduced-Scale UHV Transmission Tower-Line System Subjected to Near-Fault Ground Motions
    Tian, Li
    Zhou, Mengyao
    Pan, Haiyang
    Xin, Aiqiang
    Liu, Yuping
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (06)
  • [3] Effects of near-fault ground motions and equivalent pulses on Large Crossing Transmission Tower-line System
    Wu Gang
    Zhai Changhai
    Li Shuang
    Xie Lili
    ENGINEERING STRUCTURES, 2014, 77 : 161 - 169
  • [4] Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions
    Tian L.
    Bi W.
    Liu J.
    Dong X.
    Xin A.
    Earthquake and Structures, 2020, 19 (06): : 445 - 457
  • [5] Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions
    Tian, Li
    Bi, Wenzhe
    Liu, Juncai
    Dong, Xu
    Xin, Aiqiang
    EARTHQUAKES AND STRUCTURES, 2020, 19 (06) : 445 - 457
  • [6] ASSESSMENT OF PROBABILITY OF COLLAPSE FOR AN MRF SUBJECTED TO NEAR-FAULT GROUND MOTIONS
    Wu, Qiao-Yun
    Zhu, Hong-Ping
    Fan, Jian
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 107 - 111
  • [7] Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions
    Tian, Li
    Li, Hongnan
    Liu, Guohuan
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2010, 2010
  • [8] Research on shaking table test of transmission tower-line system under near-fault earthquake
    Tian, Li
    Liu, Juncai
    Pan, Haiyang
    Niu, Yanhong
    Guo, Wei
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2018, 51 : 127 - 132
  • [9] Dynamic Responses of Long-Span Transmission Tower-Line System Subjected to Broken Wires
    夏正春
    李黎
    方秦汉
    龙晓鸿
    Journal of Southwest Jiaotong University(English Edition), 2008, (04) : 309 - 319
  • [10] Sesismic responses of long-span transmission tower-line system
    Department of Civil Engineering, Zhejiang University, Hangzhou 310027, China
    不详
    不详
    Gongcheng Lixue, 2008, 11 (212-217):