Magnetic resonance imaging in the normal fetal heart and in congenital heart disease

被引:41
作者
Votino, C. [1 ,2 ]
Jani, J. [1 ]
Damry, N. [3 ]
Dessy, H. [4 ]
Kang, X. [1 ]
Cos, T. [1 ]
Divano, L. [3 ]
Foulon, W. [2 ]
De Mey, J. [5 ]
Cannie, M. [3 ,5 ]
机构
[1] Univ Hosp Brugmann, Dept Obstet & Gynaecol, Brussels, Belgium
[2] Vrije Univ Brussel, UZ Brussel, Dept Obstet, Brussels, Belgium
[3] Univ Hosp Brugmann, Dept Radiol, Brussels, Belgium
[4] Hop Univ Enfants Reine Fabiola, Dept Pediat Cardiol, Brussels, Belgium
[5] Vrije Univ Brussel, UZ Brussel, Dept Radiol, Brussels, Belgium
关键词
congenital heart disease; fetal heart; magnetic resonance imaging; prenatal diagnosis; PRELIMINARY EXPERIENCE; FEASIBILITY; DIAGNOSIS; FETUS; ECHOCARDIOGRAPHY; DEFECTS; LIFE; MRI;
D O I
10.1002/uog.10061
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate prospectively the feasibility of magnetic resonance imaging (MRI) for assessment of the fetal heart for congenital heart disease (CHD). Methods This was a cross-sectional study, including 66 fetuses with a normal heart and 40 with CHD. The fetal heart was examined on MRI using axial steady-state free precession (SSFP) sequences. Regression analysis was used to investigate the effect on the ability to visualize cardiac anatomy of gestational age at examination, maternal body mass index, presence of fetal cardiac abnormality, fetal movements, fetal lie and twinning. The sensitivity and specificity of detecting cardiac defects were calculated. Results The four-chamber view was visualized in 98.1% of fetuses. The sensitivity of detecting a cardiac defect on the four-chamber view was 88% and the specificity 96%. The ability to visualize the left and right outflow tracts was only influenced by the presence of fetal movements: for the left outflow tract 94.4 vs. 50.0% visualization and for the right outflow tract 92.6 vs. 53.8% visualization without and with fetal movements, respectively. The sensitivity of detecting a cardiac defect of the left outflow tract was 63% and the specificity 100%, while sensitivity and specificity were 59 and 97%, respectively, for the right outflow tract. Conclusions Despite the use of SSFP sequences, MRI in the fetal heart remains of limited value. It can only be used as a second-line approach for abnormalities of the four-chamber view suspected at prenatal ultrasound. Copyright. 2012 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 26 条
[1]   Detection of transposition of the great arteries in fetuses reduces neonatal morbidity and mortality [J].
Bonnet, D ;
Coltri, A ;
Butera, G ;
Fermont, L ;
Le Bidois, J ;
Kachaner, J ;
Sidi, D .
CIRCULATION, 1999, 99 (07) :916-918
[2]   FETAL ECHOCARDIOGRAPHY - ACCURACY AND LIMITATIONS IN A POPULATION AT HIGH AND LOW-RISK FOR HEART-DEFECTS [J].
BROMLEY, B ;
ESTROFF, JA ;
SANDERS, SP ;
PARAD, R ;
ROBERTS, D ;
FRIGOLETTO, FD ;
BENACERRAF, BR .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 166 (05) :1473-1481
[3]   Fetal magnetic resonance imaging: luxury or necessity? [J].
Cannie, M. ;
Jani, J. ;
Dymarkowski, S. ;
Deprest, J. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (05) :471-476
[4]  
Carvalho J S, 2005, Minerva Cardioangiol, V53, P129
[5]   Preliminary investigations into a new method of functional assessment of the fetal heart using a novel application of 'real-time' cardiac magnetic resonance imaging [J].
Fogel, MA ;
Wilson, RD ;
Flake, A ;
Johnson, M ;
Cohen, D ;
McNeal, G ;
Tian, ZY ;
Rychik, J .
FETAL DIAGNOSIS AND THERAPY, 2005, 20 (05) :475-480
[6]   Fetal anomalies: Comparison of MR imaging and US for diagnosis [J].
Frates, MC ;
Kumar, AJ ;
Benson, CB ;
Ward, VL ;
Tempany, CM .
RADIOLOGY, 2004, 232 (02) :398-404
[7]   Feasibility of fetal cardiac magnetic resonance imaging:: preliminary experience [J].
Gorincour, G. ;
Bourliere-Najean, B. ;
Bonello, B. ;
Fraisse, A. ;
Philip, N. ;
Potier, A. ;
Kreitmann, B. ;
Petit, P. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (01) :105-108
[8]   Timing of presentation and postnatal outcome of infants suspected of having coarctation of the aorta during fetal life [J].
Head, CEG ;
Jowett, VC ;
Sharland, GK ;
Simpson, JM .
HEART, 2005, 91 (08) :1070-1074
[9]   The impact of maternal obesity on midtrimester sonographic visualization of fetal cardiac and craniospinal structures [J].
Hendler, I ;
Blackwell, SC ;
Bujold, E ;
Treadwell, MC ;
Wolfe, HM ;
Sokol, RJ ;
Sorokin, Y .
INTERNATIONAL JOURNAL OF OBESITY, 2004, 28 (12) :1607-1611
[10]   The incidence of congenital heart disease [J].
Hoffman, JIE ;
Kaplan, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (12) :1890-1900