Ozone generation characteristics by superimposed discharge in oxygen-fed ozonizer

被引:24
作者
Ahn, HS [1 ]
Hayashi, N [1 ]
Ihara, S [1 ]
Yamabe, C [1 ]
机构
[1] Saga Univ, Fac Sci & Engn, Dept Elect & Elect Engn, Saga 8408502, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 2003年 / 42卷 / 10期
关键词
superimposed discharge; surface discharge; pulsed corona discharge;
D O I
10.1143/JJAP.42.6578
中图分类号
O59 [应用物理学];
学科分类号
摘要
A superposition type ozonizer has been proposed to achieve relatively high ozone concentration and high ozone generation efficiency. A high-pulsed voltage and a 60 Hz ac voltage are simultaneously applied to the same reaction volume in order to improve the ozone generation yield in a wide discharge gap. The ozone concentration of the superimposed discharge consisting of surface discharge and pulsed corona discharge was approximately two times larger than that obtained by an individual discharge. It was observed that the cross-section of the superimposed discharge extended is observed to be approximately 20% at maximum. The emission intensity of the superimposed discharge shows about two times larger than that of the individual discharge at maximum due to the increased electron temperature. The increment of local electric field in the discharge region causes the superposition effect.
引用
收藏
页码:6578 / 6583