Micro-pumping flow system for spectrophotometric determination of anionic surfactants in water

被引:48
作者
Lavorante, AF
Morales-Rubio, A
de la Guardia, M
Reis, BF
机构
[1] Univ Valencia, Dept Analyt Chem, Fac Chem, E-46100 Burjassot, Spain
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
micro-pump; surfactants determination; methyl orange; minimisation;
D O I
10.1007/s00216-004-3029-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel procedure has been developed for spectrophotometric determination of anionic surfactants in water using a solenoid micro-pump as fluid-propulsion device. The proposed method is based on substitution of methyl orange ( MO) by anionic surfactants in the formation of an ion-pair with the cetyl pyridine ion (CPC+) at pH 5.0. The flow network comprised four solenoid micro-pumps which, under microcomputer control, enabled sample and reagent introduction, and homogenisation in the reaction zone. The system is flexible and simple to operate and control, and sensitive and precise. The analytical plot for the anionic surfactant was linear between 1.43 x 10(-6) and 1.43 x 10(-5) mol L-1 (0.5 to 5.0 mg L-1; R=0.997, n=5). The relative standard deviation was 0.8% (n=11) for a sample containing 5.74 x 10(-6) mol L-1 ( 2 mg L-1) surfactant. The limit of detection was 9.76 x 10(-8) mol L-1 (0.034 mg L-1) and the sampling throughput was 60 determinations per hour. The results obtained for washing-water samples were comparable with those obtained by use of the reference method, and no significant differences at the 95% confidence level were observed.
引用
收藏
页码:1305 / 1309
页数:5
相关论文
共 20 条
[1]  
[Anonymous], 1995, STANDARD METHODS EXA, V19th
[2]   Sequential injection system in flame atomic absorption spectrometry for the determination of calcium and magnesium in mineral waters [J].
Araújo, AN ;
Costa, RCC ;
Lima, JLFC ;
Reis, BF .
ANALYTICA CHIMICA ACTA, 1998, 358 (02) :111-119
[3]   Spectrophotometric determination of phytic acid in plant extracts using a multi-pumping flow system [J].
Carneiro, JMT ;
Zagatto, EAG ;
Santos, JLM ;
Lima, JLFC .
ANALYTICA CHIMICA ACTA, 2002, 474 (1-2) :161-166
[4]   In-line TiO2-assisted photodigestion of organic matter in aqueous solution for voltammetric flow analysis of heavy metals in water samples [J].
Cavicchioli, A ;
Gutz, IGR .
ANALYTICA CHIMICA ACTA, 2001, 445 (02) :127-138
[5]   Multi-pumping flow system for spectrophotometric determination of bromhexine [J].
Dias, ACB ;
Santos, JLM ;
Lima, JLFC ;
Zagatto, EAG .
ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) :107-113
[6]   Flow injection spectrophotometric determination of anionic surfactants using methyl orange as chromogenic reagent [J].
He, QH ;
Chen, HW .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (03) :270-274
[7]   Spectrophotometric method for the determination of an anionic surfactant without liquid-liquid extraction [J].
Kamaya, M ;
Tomizawa, Y ;
Nagashima, K .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :157-161
[8]   SPECTROPHOTOMETRIC DETERMINATION OF ANIONIC SURFACTANTS IN SEA-WATER BASED ON ION-PAIR EXTRACTION WITH BIS[2-(5-TRIFLUOROMETHYL-2-PYRIDYLAZO)-5-DIETHYLAMINOPHENOLATO]COBALT(III) AS COUNTER ION [J].
KASAHARA, I ;
HASHIMOTO, K ;
KAWABE, T ;
KUNITA, A ;
MAGAWA, K ;
HATA, N ;
TAGUCHI, S ;
GOTO, K .
ANALYST, 1995, 120 (06) :1803-1807
[9]   Rapid determination of anionic surfactants by improved spectrophotometric method using methylene blue [J].
Koga, M ;
Yamamichi, Y ;
Nomoto, Y ;
Irie, M ;
Tanimura, T ;
Yoshinaga, T .
ANALYTICAL SCIENCES, 1999, 15 (06) :563-568
[10]  
LAMB JC, 1985, WATER QUALITY CONTRO, P384