Ex Vivo Visualization of the Mouse Otoconial Layer Compared With Micro-Computed Tomography

被引:6
作者
Honda, Keiji [1 ]
Noguchi, Yoshihiro [1 ]
Kawashima, Yoshiyuki [1 ]
Takahashi, Masatoki [1 ]
Nishio, Ayako [1 ]
Kitamura, Ken [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Otorhinolaryngol, Tokyo 1138519, Japan
关键词
Three-dimensional; Atp2b2; Micro-computed tomography; Wriggle mouse Sagami; CA2+-ATPASE ISOFORM 2; INNER-EAR; POINT MUTATION; MEMBRANE; DEAFNESS; COCHLEA; SAGAMI; BONE;
D O I
10.1097/MAO.0000000000000376
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis Micro-computed tomography (micro-CT) is useful for assessing the 3-dimensional (3D) morphology and age-related changes of the otoconial layer. Background Wriggle mouse Sagami (WMS) is a mutant of the plasma membrane Ca2+ ATPase type2 gene (Atp2b2) with deficits in the saccular otoconia. We examined the effectiveness of micro-CT in evaluating the otoconial layer of WMS and C57BL/6J mice. Methods Otic capsules of C57BL/6J mice at different fixation time were examined using micro-CT to evaluate the effects of the fixation time on the otoconial layer. Otic capsules of Atp2b2(wri/wri), Atp2b2(wri/+), and Atp2b2(+/+) mice at P14, P21, and the age of 3 months were used to analyze age-related changes in the otoconial layer. A series of cross-section and 3D reconstructed images of the otoconial layer were obtained. The micro-CT findings were compared with the otic capsule findings cleared in methyl salicylate using stereomicroscopy. Results Micro-CT produced high-resolution images of the otoconial layer, thereby providing information regarding the spatial configuration and 3D curvature. There were no changes between the different fixation times. In the Atp2b2(wri/+) and Atp2b2(+/+) mice, the saccular and utricular otoconial layers were normal among all age groups. In the Atp2b2(wri/wri) mice, the saccular otoconial layer decreased on P14 and was absent on P21, whereas the utricular otoconial layer disappeared at 3 months of age. Conclusion We obtained precise information regarding the mouse otoconial layer with minimum artifacts. This method is expected to improve our understanding of the physiologic function and age-related changes in otolith organs.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [41] Microstructure Study of Normal Lunates with Micro-computed Tomography
    肖滋润
    熊革
    Shi-gong GUO
    杜传超
    张友乐
    Current Medical Science, 2017, (03) : 384 - 389
  • [42] Micro-computed tomography-current status and developments
    Ritman, EL
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2004, 6 : 185 - 208
  • [43] Advantages and limitations of micro-computed tomography and computed tomography imaging of archaeological textiles and coffins
    Lipkin, Sanna
    Karjalainen, Ville-Pauli
    Puolakka, Hanna-Leena
    Finnila, Mikko A. J.
    HERITAGE SCIENCE, 2023, 11 (01)
  • [44] Micro-computed tomography for the quantification of blocked fibers in hemodialyzers
    Vanommeslaeghe, Floris
    Van Biesen, Wim
    Dierick, Manuel
    Boone, Matthieu
    Dhondt, Annemieke
    Eloot, Sunny
    SCIENTIFIC REPORTS, 2018, 8
  • [45] Micro-computed tomography as a platform for exploring Drosophila development
    Schoborg, Todd A.
    Smith, Samantha L.
    Smith, Lauren N.
    Morris, H. Douglas
    Rusan, Nasser M.
    DEVELOPMENT, 2019, 146 (23):
  • [46] Cochlear pharmacokinetics - Micro-computed tomography and learning-prediction modeling for transport parameter determination
    Moudgalya, Sanketh S.
    Wilson, Kevin
    Zhu, Xiaoxia
    Budzevich, Mikalai M.
    Walton, Joseph R.
    Cahill, Nathan D.
    Frisina, Robert D.
    Borkholder, David A.
    HEARING RESEARCH, 2019, 380 : 46 - 59
  • [47] Correlation of Subchondral Bone Density and Structure from Plain Radiographs with Micro Computed Tomography Ex Vivo
    Jukka Hirvasniemi
    Jérôme Thevenot
    Harri T. Kokkonen
    Mikko A. Finnilä
    Mikko S. Venäläinen
    Timo Jämsä
    Rami K. Korhonen
    Juha Töyräs
    Simo Saarakkala
    Annals of Biomedical Engineering, 2016, 44 : 1698 - 1709
  • [48] Correlation of Subchondral Bone Density and Structure from Plain Radiographs with Micro Computed Tomography Ex Vivo
    Hirvasniemi, Jukka
    Thevenot, Jerome
    Kokkonen, Harri T.
    Finnila, Mikko A.
    Venalainen, Mikko S.
    Jamsa, Timo
    Korhonen, Rami K.
    Toyras, Juha
    Saarakkala, Simo
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (05) : 1698 - 1709
  • [49] Micro-architecture study of the normal odontoid with micro-computed tomography
    Wang, Wei
    Li, Zhijun
    Qi, Yingna
    Chen, Lianxiang
    Yi, Ping
    Yang, Feng
    Tang, Xiangsheng
    Tan, Mingsheng
    JOURNAL OF SPINAL CORD MEDICINE, 2020, 43 (02) : 211 - 216
  • [50] Nondestructive micro-computed tomography for biological imaging and quantification of scaffold-bone interaction in vivo
    van Lenthe, G. Harry
    Hagenmueller, Henri
    Bohner, Marc
    Hollister, Scott J.
    Meinel, Lorenz
    Mueller, Ralph
    BIOMATERIALS, 2007, 28 (15) : 2479 - 2490