Impact of the rapid-exchange versus over-the-wire technique on procedural complications of renal artery angioplasty

被引:5
作者
Amighi, J [1 ]
Sabeti, S [1 ]
Dick, P [1 ]
Schlager, O [1 ]
Ahmadi, R [1 ]
Minar, E [1 ]
Schillinger, M [1 ]
机构
[1] Med Univ Vienna, Dept Internal Med 2, Div Angiol, A-1090 Vienna, Austria
关键词
renal artery; stenosis; angioplasty; stent; technique; rapid-exchange catheter; over-the-wire catheter;
D O I
10.1583/04-1467.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To investigate whether the use of rapid-exchange (RX) systems adds to the safety of percutaneous renal artery procedures compared to the conventional over-the-wire (OTW) technique. Methods: The interventional registry in our department was interrogated to identify patients who underwent plain balloon angioplasty and/or stent implantation for > 60% renal artery stenosis and intractable hypertension or decreasing renal function between 1998 and 2004. In this time period, 63 consecutive patients (36 men; mean age 67 years, range 57-80) underwent 78 renal artery angioplasty procedures. The first 46 procedures were done using a transfemoral OTW technique via 7-F sheaths; the following 32 procedures were performed with an RX system via a transfemoral 6-F access. Duration of fluoroscopy, amount of contrast agent, course of serum creatinine, and complications were compared between OTW and RX approaches. Results: Duration of fluoroscopy (median 13.1 versus 11.1 minutes, p = 0.099) and primary technical success (94% versus 97%, p = 0.64) were not significantly different between the OTW and RX approaches, but significantly less contrast agent was needed with the RX system (median 215 versus 140 mL, p < 0.001). Complications, all minor, occurred significantly more often with the OTW (11/46, 24%) compared to the RX system (2/32, 6%; p = 0.040) and included misplaced stents, prolonged severe hyper/hypotension, transient renal impairment, and puncture site complications. In particular, the rates of increased serum creatinine within 24 hours were higher in the OTW patients compared to the RX group (20% versus 3%, respectively, for > 25% increase [p = 0.041] and 9% versus 0% for > 50% increase [p = 0.087]). Conclusions: Rapid exchange systems seem to add to the safety of percutaneous renal artery interventions. This likely may be due to a variety of causes, including lower doses of contrast medium, shorter duration of fluoroscopy, and smaller device diameters.
引用
收藏
页码:233 / 239
页数:7
相关论文
共 25 条
  • [1] [Anonymous], COCHRANE DATABASE SY, DOI DOI 10.1002/14651858.CD002944
  • [2] The erasme study: A multicenter study on the safety and technical results of the Palmaz stent used for the treatment of atherosclerotic ostial renal artery stenosis
    Bakker, J
    Goffette, PP
    Henry, M
    Mali, WPTM
    Melki, JP
    Moss, JG
    Rabbia, C
    Therasse, E
    Thomson, KR
    Thurnher, S
    Vignali, C
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 22 (06) : 468 - 474
  • [3] Complications during renal artery stent placement for atherosclerotic ostial stenosis
    Beek, FJA
    Kaatee, R
    Beutler, JJ
    vanderVen, PJ
    Mali, WPTM
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 20 (03) : 184 - 190
  • [4] Endovascular revascularization of renal artery stenosis: Technical and clinical results
    Bush, RL
    Najibi, S
    MacDonald, J
    Lin, PH
    Chaikof, EL
    Martin, LG
    Lumsden, AB
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (05) : 1041 - 1049
  • [5] FOLLOW-UP OF PRIMARY PALMAZ-SCHATZ STENT PLACEMENT FOR ATHEROSCLEROTIC RENAL-ARTERY STENOSIS
    DORROS, G
    JAFF, M
    JAIN, A
    DUFEK, C
    MATHIAK, L
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (15) : 1051 - 1055
  • [6] Renal stenting from the radial artery: A novel approach
    Kessel, DO
    Robertson, L
    Taylor, EJ
    Patel, JV
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 26 (02) : 146 - 149
  • [7] Stent placement for renal arterial stenosis: Where do we stand? A meta-analysis
    Leertouwer, TC
    Gussenhoven, EJ
    Bosch, JL
    van Jaarsveld, BC
    van Dijk, LC
    Deinum, J
    Man in't Veld, AJ
    [J]. RADIOLOGY, 2000, 216 (01) : 78 - 85
  • [8] RADIATION EXPOSURE - COMPARISON OF RAPID EXCHANGE AND CONVENTIONAL OVER-THE-WIRE CORONARY ANGIOPLASTY SYSTEMS
    LINNEMEIER, TJ
    MCCALLISTER, SH
    LIPS, DL
    KLETTE, MA
    ROTHBAUM, DA
    BALL, MW
    LANDIN, RJ
    HODES, ZI
    RIDDELL, RV
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (01): : 11 - 14
  • [9] Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis
    Müller-Hülsbeck, S
    Jahnke, T
    Grimm, J
    Behm, C
    Hilbert, C
    Frahm, C
    Biederer, J
    Brossmann, J
    Heller, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (03): : 335 - 341
  • [10] Nikolsky Eugenia, 2003, Rev Cardiovasc Med, V4 Suppl 1, pS7