Fiducial-free CyberKnife radiosurgery for residual metastatic spinal tumor after decompression and instrumentation

被引:7
作者
Park, Jin Hoon [2 ]
Park, Jae Hong [1 ]
Cho, Young Hyun [1 ]
Jeon, Sang Ryong [1 ]
Kim, Chang Jin [1 ]
Roh, Sung Woo [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Neurol Surg,Cyberknife Ctr, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Gangneung Asan Hosp, Dept Neurol Surg, Kangnung, South Korea
关键词
CyberKnife; Fiducial free; Spinal metastasis; Spinal radiosurgery; Residual tumor; STEREOTACTIC RADIOSURGERY; LESIONS; EXPERIENCE; ACCURACY;
D O I
10.1016/j.jocn.2011.12.027
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Stereotactic spinal radiotherapy is a promising technology for use in the multidisciplinary management of benign and malignant spinal tumors. We present two patients with residual metastatic spinal tumors and their treatment with CyberKnife (Accuray, Sunnyvale, CA, USA) after decompression and instrumentation, one of which was successful and the other not. A 73-year-old male patient was admitted with bilateral extremity weakness (Grade IV) and voiding difficulty that had developed 2 days previously. CyberKnife treatment for the residual tumor after surgery with decompression and instrumentation was attempted, but could not be performed due to imaging interference caused by the instrumentation. A second patient, a 49-year-old male, was admitted with right extremity weakness and voiding difficulty that had developed 5 months previously. In this patient, we were able to perform CyberKnife treatment on the residual tumor after decompression and instrumentation. Based on these two patients, we believe that fiducial-free CyberKnife treatment is not suitable for treatment of residual metastatic spinal tumors at the upper thoracic levels, after decompression with instrumentation. This is due to the difficulties in matching digitally reconstructed radiographs with live radiographic images, as a result of the larger inclination and smaller vertebral body surface at the upper thoracic level. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1573 / 1575
页数:3
相关论文
共 14 条
[1]   CyberKnife stereotactic radiosurgical treatment of spinal tumors for pain control and quality of life [J].
Degen, JW ;
Gagnon, GJ ;
Voyadzis, JM ;
McRae, DA ;
Lunsden, M ;
Dieterich, S ;
Molzahn, I ;
Henderson, FC .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (05) :540-549
[2]   PATIENT MOTION AND TARGETING ACCURACY IN ROBOTIC SPINAL RADIOSURGERY: 260 SINGLE-FRACTION FIDUCIAL-FREE CASES [J].
Fuerweger, Christoph ;
Drexler, Christian ;
Kufeld, Markus ;
Muacevic, Alexander ;
Wowra, Berndt ;
Schlaefer, Alexander .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03) :937-945
[3]  
Furweger Christoph, 2010, J Appl Clin Med Phys, V12, P3446
[4]   CyberKnife radiosurgery for breast cancer spine metastases - A matched-pair analysis [J].
Gagnon, Gregory J. ;
Henderson, Fraser C. ;
Gehan, Edmund A. ;
Sanford, Donna ;
Collins, Brian T. ;
Moulds, Jefferson C. ;
Dritschilo, Anatoly .
CANCER, 2007, 110 (08) :1796-1802
[5]  
Gerszten PC, 2004, NEUROSURGERY, V55, P89, DOI 10.1227/01.NEU.0000126873.00845.A7
[6]   Cyberknife radiosurgery for metastatic spine tumors [J].
Gerszten, PC ;
Welch, WC .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2004, 15 (04) :491-+
[7]   Evaluation of CyberKnife frameless real-time image-guided stereotactic radiosurgery for spinal lesions [J].
Gerszten, PC ;
Ozhasoglu, C ;
Burton, SA ;
Vogel, W ;
Atkins, B ;
Kalnicki, S ;
Welch, WC .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2003, 81 (1-4) :84-89
[8]  
Gerszten Peter C, 2002, Neurosurg Focus, V13, pe2
[9]   Efficacy and cost-effectiveness analysis of external beam and stereotactic body radiation therapy in the treatment of spine metastases: a matched-pair analysis Clinical article [J].
Haley, Marsha L. ;
Gerszten, Peter C. ;
Heron, Dwight E. ;
Chang, Yue-Fang ;
Atteberry, Dave S. ;
Burton, Steven A. .
JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (04) :537-542
[10]   The accuracy of dose localization for an image-guided frameless radiosurgery system [J].
Murphy, MJ ;
Cox, RS .
MEDICAL PHYSICS, 1996, 23 (12) :2043-2049