Ultrasensitive electrochemical immunoassay based on graphene oxide-Ag composites for rapid determination of clenbuterol

被引:27
作者
Bai, Jing [1 ]
Lai, Yanjun [1 ]
Jiang, Dawei [1 ]
Zeng, Yanbo [1 ]
Xian, Yuezhong [1 ]
Xiao, Fei [1 ]
Zhang, Ningdan [1 ]
Hou, Jie [1 ]
Jin, Litong [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
CARBON NANOTUBE; BETA-AGONISTS; LIQUID; IMMUNOSENSOR; NANOMATERIALS; FABRICATION; CHEMISTRY; SHEETS; URINE;
D O I
10.1039/c2an35473j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the development of an ultrasensitive amperometric biosensor based on Ag nanoparticles-decorated graphene oxide nanosheets (GO) (Ag-GO) for the rapid detection of clenbuterol (CLB). The morphology and structure of the Ag-GO labeled CLB (Ag-GO-CLB) were characterized by transmission electron microscope (TEM), atomic force microscope (AFM), and ultraviolet-visible spectroscope (UV-vis). The immunosensor was prepared by covalently immobilizing capture antibodies on a multi-walled carbon nanotubes-modified glassy carbon electrode. Through competitive immunoreactions, the Ag-GO-CLB nanocomposites were captured on the immunosensor and the silver was measured by positive differential pulse voltammetry (DPV) in KCl solution for the detection of antigen. The experimental results show a linear response over the range from 0.01 to 10.0 ng mL(-1) with a lower detection limit of 6.8 pg mL(-1) (signal-to-noise ratio of 3). The Ag-GO based immunosensor offers a simple and convenient route for metal-immunoassay labels, which can avoid the complicated and time-consuming dissolving of metal component for ultrasensitive determination. Moreover, the electrochemical immunoassay shows acceptable specificity and stability and is suitable for the determination of CLB in real samples.
引用
收藏
页码:4349 / 4355
页数:7
相关论文
共 52 条
[1]   Determination of clenbuterol in human urine and serum by solid-phase microextraction coupled to liquid chromatography [J].
Aresta, A. ;
Calvano, C. D. ;
Palmisano, F. ;
Zambonin, C. G. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (03) :641-645
[2]   Functional Composite Materials Based on Chemically Converted Graphene [J].
Bai, Hua ;
Li, Chun ;
Shi, Gaoquan .
ADVANCED MATERIALS, 2011, 23 (09) :1089-1115
[3]  
Biancotto G, 1999, J MASS SPECTROM, V34, P1346, DOI 10.1002/(SICI)1096-9888(199912)34:12<1346::AID-JMS893>3.0.CO
[4]  
2-#
[5]   DETERMINATION OF PROPRANOLOL, LABETALOL AND CLENBUTEROL IN RAT-BRAIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOTTERBLOM, MHA ;
FEENSTRA, MGP ;
ERDTSIECKERNSTE, EBHW .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01) :121-126
[6]   Modeling of graphite oxide [J].
Boukhvalov, D. W. ;
Katsnelson, M. I. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (32) :10697-10701
[7]   Electrochemistry of graphene: not such a beneficial electrode material? [J].
Brownson, Dale A. C. ;
Munro, Lindsey J. ;
Kampouris, Dimitrios K. ;
Banks, Craig E. .
RSC ADVANCES, 2011, 1 (06) :978-988
[8]   Graphene electrochemistry: an overview of potential applications [J].
Brownson, Dale A. C. ;
Banks, Craig E. .
ANALYST, 2010, 135 (11) :2768-2778
[9]   Electrocatalytic reduction of hydrogen peroxide by silver particles patterned on single-walled carbon nanotubes [J].
Bui, Minh-Phuong Ngoc ;
Pham, Xuan-Hung ;
Nan, Kwi Nam ;
Li, Cheng Ai ;
Kim, Yong Shin ;
Seong, Gi Hun .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (01) :436-441
[10]   Electromechanical resonators from graphene sheets [J].
Bunch, J. Scott ;
van der Zande, Arend M. ;
Verbridge, Scott S. ;
Frank, Ian W. ;
Tanenbaum, David M. ;
Parpia, Jeevak M. ;
Craighead, Harold G. ;
McEuen, Paul L. .
SCIENCE, 2007, 315 (5811) :490-493