Comparison of three non-invasive quantitative measurement systems for the pivot shift test

被引:40
作者
Araujo, Paulo H. [1 ]
Ahlden, Mattias [1 ,2 ]
Hoshino, Yuichi [1 ,3 ]
Muller, Bart [1 ]
Moloney, Gele [1 ]
Fu, Freddie H. [1 ]
Musahl, Volker [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Sahlgrenska Univ, Dept Orthopaed, Gothenburg, Sweden
[3] Kobe Univ, Dept Orthopaed Surg, Kobe, Hyogo 657, Japan
关键词
ACL; Pivot shift; Quantitative analysis; Acceleration; Anterior tibial translation; IN-VIVO MEASUREMENT; ACL RECONSTRUCTION; KNEE-JOINT; CLINICAL EXAMINATION; KINEMATICS; MOTIONS;
D O I
10.1007/s00167-011-1862-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to evaluate three different non-invasive measuring devices for the pivot shift phenomenon with reference to direct bony movement measured by an electromagnetic device rigidly attached to the tibia and femur. Methods A lower body cadaveric specimen was prepared to create a positive pivot shift in both knees. Twelve expert knee surgeons from worldwide performed their preferred pivot shift technique three times in each knee. After watching an instructional video, the examiners used a standardized technique to perform three additional pivot shift maneuvers in each knee. An electromagnetic tracking system, rigidly attached to femur and tibia, was used to provide reference measurements during the pivot shift test. Three different devices were correlated to the reference method and evaluated in this study: (1) Electromagnetic tracking system with skin sensors; (2) Triaxial accelerometer system; (3) Simple image analysis. Results When results from both pivot shift techniques (preferred and standardized) were combined, the electromagnetic tracking system with skin sensors showed positive correlation with the reference measurement for acceleration and translation parameters (r = 0.88 and r = 0.67, respectively; both P < 0.01); The triaxial accelerometer system demonstrated good correlation with the reference measurement for acceleration (r = 0.75; P < 0.001). The image analysis system was poorly correlated to the translation of the reference measurement (r = 0.24; P < 0.01). Conclusion The electromagnetic tracking system with skin sensors provided the best correlation with the reference method. The triaxial accelerometer showed also a good correlation and the image analysis system showed a positive, but poor correlation with the reference method. More research is needed in order to validate simple and non-invasive devices for clinical application.
引用
收藏
页码:692 / 697
页数:6
相关论文
共 29 条
[1]   A prospective randomised study of anatomical single-bundle versus double-bundle anterior cruciate ligament reconstruction: quantitative evaluation using an electromagnetic measurement system [J].
Araki, Daisuke ;
Kuroda, Ryosuke ;
Kubo, Seiji ;
Fujita, Norifumi ;
Tei, Katsumasa ;
Nishimoto, Koji ;
Hoshino, Yuichi ;
Matsushita, Takehiko ;
Matsumoto, Tomoyuki ;
Nagamune, Koki ;
Kurosaka, Masahiro .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (03) :439-446
[2]   Lateral compartment translation predicts the grade of pivot shift: a cadaveric and clinical analysis [J].
Bedi, Asheesh ;
Musahl, Volker ;
Lane, Clayton ;
Citak, Musa ;
Warren, Russell F. ;
Pearle, Andrew D. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (09) :1269-1276
[3]   Clinical diagnosis of an anterior cruciate ligament rupture: A meta-analysis [J].
Benjammse, A ;
Gokeler, A ;
van der Schans, CP .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (05) :267-288
[4]   Clinical relevance of static and dynamic tests after anatomical double-bundle ACL reconstruction [J].
Bignozzi, Simone ;
Zaffagnini, Stefano ;
Lopomo, Nicola ;
Fu, Freddie H. ;
Irrgang, James J. ;
Marcacci, Maurilio .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (01) :37-42
[5]   ASSESSMENT OF THE MENISCI AND CRUCIATE LIGAMENTS - AN AUDIT OF CLINICAL-PRACTICE [J].
BOEREE, NR ;
ACKROYD, CE .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1991, 22 (04) :291-294
[6]   Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament [J].
Bull, AMJ ;
Earnshaw, PH ;
Smith, A ;
Katchburian, MV ;
Hassan, ANA ;
Amis, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (07) :1075-1081
[7]   Comparison of the Clinical Outcome of Double-Bundle, Anteromedial Single-Bundle, and Posterolateral Single-Bundle Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Graft With Minimum 2-Year Follow-up [J].
Fujita, Norifumi ;
Kuroda, Ryosuke ;
Matsumoto, Tomoyuki ;
Yamaguchi, Motoi ;
Yagi, Masayoshi ;
Matsumoto, Akio ;
Kubo, Seiji ;
Matsushita, Takehiko ;
Hoshino, Yuichi ;
Nishimoto, Koji ;
Araki, Daisuke ;
Kurosaka, Masahiro .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (07) :906-913
[8]  
GALWAY HR, 1980, CLIN ORTHOP RELAT R, P45
[9]   A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[10]   EVALUATION OF ACUTE TRAUMATIC HEMARTHROSIS OF THE KNEE-JOINT [J].
HARDAKER, WT ;
GARRETT, WE ;
BASSETT, FH .
SOUTHERN MEDICAL JOURNAL, 1990, 83 (06) :640-644