Development of a quality control program for a Cone Beam CT Imaging System

被引:1
作者
Benitez, Ricardo Betancourt [1 ]
Ning, Ruola [1 ]
Conover, David [1 ]
Zhang, Yan [1 ]
Cai, Weixing [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
quality control; cone beam CT; MTF; NPS; noise level; uniformity; linearity;
D O I
10.1117/12.770427
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Routine quality control assessments of medical equipment are crucial for an accurate patient medical treatment as well as for the safety of the patient and staff involved. These regular evaluations become especially important when dealing with radiation-emitting equipment. Therefore, a quality control (QC) program has been developed to quantitatively evaluate imaging systems by measuring standard parameters related to image quality such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS), uniformity, linearity and noise level among others. First, the methods of evaluating the aforementioned parameters have been investigated using a cone beam CT imaging system. Different exposure techniques, phantoms, acquisition modes of the flat panel detector (FPD) and reconstruction algorithms relevant to a clinical environment were all included in this investigation. Second, using the results of the first part of this study, a set of parameters for the QC program was established that yields both, an accurate depiction of the system image quality and an integrated program for easy and practical implementation. Lastly, this QC program will be implemented and practiced in our cone beam CT imaging system. The results using our available phantoms demonstrate that the QC program is adequate to evaluate stability and image quality of this system since it provides comparable parameters to other QC programs.
引用
收藏
页数:9
相关论文
共 50 条
[31]   Technical assessment of a cone-beam CT scanner for otolaryngology imaging: Image quality, dose, and technique protocols [J].
Xu, J. ;
Reh, D. D. ;
Carey, J. P. ;
Mahesh, M. ;
Siewerdsen, J. H. .
MEDICAL PHYSICS, 2012, 39 (08) :4932-4942
[32]   Simulation of mammograms & tomosynthesis imaging with cone beam breast CT images [J].
Han, Tao ;
Shaw, Chris C. ;
Chen, Lingyun ;
Lai, Chao-jen ;
Liu, Xinming ;
Wang, Tianpeng .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
[33]   Assessment of the central artifact in cone beam CT imaging with an offset geometry [J].
Zhang, Guozhi ;
Jacobs, Reinhilde ;
Nuyts, Johan ;
Bosmans, Hilde .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[34]   Geometry calibration method for a cone-beam CT system [J].
Yang, Hongkai ;
Kang, Kejun ;
Xing, Yuxiang .
MEDICAL PHYSICS, 2017, 44 (05) :1692-1706
[35]   Development and quality characterization of a novel CT system [J].
Schegerer, Alexander A. ;
Lingenheil, Martin ;
Klaften, Matthias ;
Foerster, Thomas ;
de Angelis, Martin Hrabe ;
Hoeschen, Christoph .
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
[36]   A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization [J].
Zbijewski, W. ;
De Jean, P. ;
Prakash, P. ;
Ding, Y. ;
Stayman, J. W. ;
Packard, N. ;
Senn, R. ;
Yang, D. ;
Yorkston, J. ;
Machado, A. ;
Carrino, J. A. ;
Siewerdsen, J. H. .
MEDICAL PHYSICS, 2011, 38 (08) :4700-4713
[37]   Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition [J].
Santoso, Andrew P. ;
Song, Kwang H. ;
Qin, Yujiao ;
Gardner, Stephen J. ;
Liu, Chang ;
Chetty, Indrin J. ;
Movsas, Benjamin ;
Ajlouni, Munther ;
Wen, Ning .
RADIATION ONCOLOGY, 2016, 11
[38]   Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition [J].
Andrew P. Santoso ;
Kwang H. Song ;
Yujiao Qin ;
Stephen J. Gardner ;
Chang Liu ;
Indrin J. Chetty ;
Benjamin Movsas ;
Munther Ajlouni ;
Ning Wen .
Radiation Oncology, 11
[39]   Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom [J].
Bamba, J. ;
Araki, K. ;
Endo, A. ;
Okano, T. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
[40]   X-ray scatter correction algorithm for cone beam CT imaging [J].
Ning, R ;
Tang, XY ;
Conover, D .
MEDICAL PHYSICS, 2004, 31 (05) :1195-1202