Development of a quality control program for a Cone Beam CT Imaging System

被引:1
作者
Benitez, Ricardo Betancourt [1 ]
Ning, Ruola [1 ]
Conover, David [1 ]
Zhang, Yan [1 ]
Cai, Weixing [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
quality control; cone beam CT; MTF; NPS; noise level; uniformity; linearity;
D O I
10.1117/12.770427
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Routine quality control assessments of medical equipment are crucial for an accurate patient medical treatment as well as for the safety of the patient and staff involved. These regular evaluations become especially important when dealing with radiation-emitting equipment. Therefore, a quality control (QC) program has been developed to quantitatively evaluate imaging systems by measuring standard parameters related to image quality such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS), uniformity, linearity and noise level among others. First, the methods of evaluating the aforementioned parameters have been investigated using a cone beam CT imaging system. Different exposure techniques, phantoms, acquisition modes of the flat panel detector (FPD) and reconstruction algorithms relevant to a clinical environment were all included in this investigation. Second, using the results of the first part of this study, a set of parameters for the QC program was established that yields both, an accurate depiction of the system image quality and an integrated program for easy and practical implementation. Lastly, this QC program will be implemented and practiced in our cone beam CT imaging system. The results using our available phantoms demonstrate that the QC program is adequate to evaluate stability and image quality of this system since it provides comparable parameters to other QC programs.
引用
收藏
页数:9
相关论文
共 50 条
[21]   A geometric calibration method for cone beam CT system [J].
Xiang Qian ;
Wang Jue ;
Cai Yufang .
EIGHTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2016), 2016, 10033
[22]   Image quality of flat panel cone-beam CT [J].
Rose, G ;
Wiegert, J ;
Schäfer, D ;
Fiedler, K ;
Conrads, N ;
Timmer, J ;
Rasche, V ;
Noordhoek, N ;
Klotz, E ;
Koppe, R .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :677-683
[23]   Development of a beam stop array system with dual scan mode for scatter correction of cone-beam CT [J].
So Hyun Ahn ;
Jinho Choi ;
Kyu Chan Lee ;
Siyong Kim ;
Rena Lee .
Journal of the Korean Physical Society, 2014, 64 :1220-1229
[24]   Development of a Beam Stop Array System with Dual Scan Mode for Scatter Correction of Cone-beam CT [J].
Ahn, So Hyun ;
Choi, Jinho ;
Lee, Kyu Chan ;
Kim, Siyong ;
Lee, Rena .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) :1220-1229
[25]   Clinical implementation of megavoltage cone beam CT as part of an IGRT program [J].
Gonzalez, Albin ;
Bauer, Lisa ;
Kinney, Vicki ;
Crooks, Cheryl .
PROCEEDINGS OF THE NATIONAL SOCIETY OF BLACK PHYSICISTS, 2008, 991 :127-+
[26]   Development and Spatial Resolution Characterization of a Dedicated Pulsed X-ray, Cone-beam Breast CT System [J].
Gazi, Peymon ;
Yang, Kai ;
Burkett, Geroge ;
Boone, John .
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
[27]   Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms [J].
Wu, P. ;
Sisniega, A. ;
Stayman, J. W. ;
Zbijewski, W. ;
Foos, D. ;
Wang, X. ;
Khanna, N. ;
Aygun, N. ;
Stevens, R. D. ;
Siewerdsen, J. H. .
MEDICAL PHYSICS, 2020, 47 (06) :2392-2407
[28]   Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation [J].
Ning, R ;
Conover, D ;
Yu, Y ;
Cai, WX ;
Lu, XH .
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 :147-158
[29]   Intraoperative cone-beam and slot-beam CT: 3D image quality and dose with a slot collimator on the O-arm imaging system [J].
Zhang, Xiaoxuan ;
Zbijewski, Wojciech ;
Huang, Yixuan ;
Uneri, Ali ;
Jones, Craig K. ;
Lo, Sheng-Fu L. ;
Witham, Timothy F. ;
Luciano, Mark ;
Anderson, William Stanley ;
Helm, Patrick A. ;
Siewerdsen, Jeffrey H. .
MEDICAL PHYSICS, 2021, 48 (11) :6800-6809
[30]   Metal artifacts correction in cone-beam CT bone imaging [J].
Zhang, Yan ;
Ning, Ruola ;
Conover, David .
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510