Development of a quality control program for a Cone Beam CT Imaging System

被引:1
作者
Benitez, Ricardo Betancourt [1 ]
Ning, Ruola [1 ]
Conover, David [1 ]
Zhang, Yan [1 ]
Cai, Weixing [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
quality control; cone beam CT; MTF; NPS; noise level; uniformity; linearity;
D O I
10.1117/12.770427
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Routine quality control assessments of medical equipment are crucial for an accurate patient medical treatment as well as for the safety of the patient and staff involved. These regular evaluations become especially important when dealing with radiation-emitting equipment. Therefore, a quality control (QC) program has been developed to quantitatively evaluate imaging systems by measuring standard parameters related to image quality such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS), uniformity, linearity and noise level among others. First, the methods of evaluating the aforementioned parameters have been investigated using a cone beam CT imaging system. Different exposure techniques, phantoms, acquisition modes of the flat panel detector (FPD) and reconstruction algorithms relevant to a clinical environment were all included in this investigation. Second, using the results of the first part of this study, a set of parameters for the QC program was established that yields both, an accurate depiction of the system image quality and an integrated program for easy and practical implementation. Lastly, this QC program will be implemented and practiced in our cone beam CT imaging system. The results using our available phantoms demonstrate that the QC program is adequate to evaluate stability and image quality of this system since it provides comparable parameters to other QC programs.
引用
收藏
页数:9
相关论文
共 12 条
[1]  
CAREY E, 2001, RADIOLOGY, V218, P683
[2]   Spatial resolution properties in cone beam CT: A simulation study [J].
Chen, Lingyun ;
Shaw, Chris C. ;
Altunbas, Mustafa C. ;
Lai, Chao-Jen ;
Liu, Xinming .
MEDICAL PHYSICS, 2008, 35 (02) :724-734
[3]   Characterization of an amorphous silicon fluoroscopic imager [J].
Colbeth, RE ;
Allen, MJ ;
Day, DJ ;
Gilblom, DL ;
KlausmeierBrown, ME ;
Pavkovich, J ;
Seppi, EJ ;
Shapiro, EG .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :42-51
[4]   Characterization of a third generation, multi-mode sensor panel [J].
Colbeth, RE ;
Cooper, VN ;
Gilblom, DL ;
Harris, R ;
Job, ID ;
Klausmeier-Brown, ME ;
Marc, M ;
Pavkovich, J ;
Seppi, EJ ;
Shapiro, EG ;
Wright, MD ;
Yu, JM .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :491-500
[5]  
COLBETH RE, 2000, ANN M 2000, V18
[6]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[7]   A SIMPLIFIED APPROACH FOR MODULATION TRANSFER-FUNCTION DETERMINATIONS IN COMPUTED-TOMOGRAPHY [J].
NICKOLOFF, EL ;
RILEY, R .
MEDICAL PHYSICS, 1985, 12 (04) :437-442
[8]   Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology [J].
Siewerdsen, JH ;
Antonuk, LE ;
El-Mohri, Y ;
Yorkston, J ;
Huang, W ;
Cunningham, IA .
MEDICAL PHYSICS, 1998, 25 (05) :614-628
[9]   Physical characteristics of a full-field digital mammography system [J].
Suryanarayanan, S ;
Karellas, A ;
Vedantham, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 533 (03) :560-570
[10]   Development of angiography system with cone-beam reconstruction using large-area flat panel detector [J].
Suzuki, K ;
Ikeda, S ;
Ueda, K ;
Nakamura, T ;
Okabe, M ;
Kadomura, T ;
Baba, R ;
Colbeth, RE .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :488-498