High dose for prostate irradiation with image guided radiotherapy: Contribution of intensity modulation arctherapy

被引:4
作者
Jouyaux, F. [1 ]
De Crevoisier, R. [1 ,2 ,3 ]
Manens, J. -P. [1 ,2 ,3 ]
Bellec, J. [1 ]
Cazoulat, G. [2 ,3 ]
Haigron, P. [2 ,3 ]
Chira, C. [1 ]
Le Prise, E. [1 ]
Lafond, C. [1 ,2 ,3 ]
机构
[1] Ctr Eugene Marquis, F-35042 Rennes, France
[2] INSERM, U642, F-35000 Rennes, France
[3] Univ Rennes 1, LTSI, F-35000 Rennes, France
来源
CANCER RADIOTHERAPIE | 2010年 / 14卷 / 08期
关键词
3D conformal radiotherapy; Intensity-modulated radiotherapy; Dynamic conformal arc; Prostate; CONFORMAL RADIATION-THERAPY; TREATMENT-PLANNING SYSTEMS; STEP-AND-SHOOT; ARC THERAPY; QUALITY-ASSURANCE; NECK-CANCER; CLINICAL IMPLEMENTATION; SECONDARY MALIGNANCIES; CALCULATION ALGORITHMS; MULTILEAF COLLIMATOR;
D O I
10.1016/j.canrad.2010.03.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - To compare two Intensity Modulated Radiation Therapy (IMRT) techniques for prostate cancer: the Volumetric Modulated Arc Therapy (VMAT) and the "Step and Shoot" technique (S&S). Materials and methods. - VMAT and S&S plans (RX 18 MV) were created and compared (Wilcoxon test) for 10 patients. The dosimetric goal of both treatments was to deliver 46 Gy to the seminal vesicles and 80 Gy to the prostate, while respecting the dose constrains in the organs at risk of toxicity. For one patient, the two techniques were compared for dose painting and escalation in target volumes defined on MRI and registered thanks to intraprostatic fiducials. Results. - VMAT, compared to S&S, offered: an increase of the PTV2s (prostate) volume receiving 77 to 80 Gy and a decrease Of V-82 and V-83; a decrease of V-4 to V-6, V-16 to V-23, and V-69 to V-73 for the rectal wall; a decrease of V-25 for the bladder wall: a decrease of V-21 to V-43 for the femoral heads; a decrease of V-26 to V-44 and V-72 to V-80 but an increase of V-1 to V-21 and V-49 to V-60 for the healthy tissues. The Conformal Index "COIN" was better with VMAT than S&S (0.60 to 0.66). The delivered MU were significantly reduced with VMAT (8% mean) as well as the delivery time (4 min to 1.5 min). VMAT allowed delivering theorically 90 Gy in the peripheral zone and 100 Gy in the tumor. Conclusion. - In case of prostate irradiation, VMAT shows improvement compared with S&S. In particular, organs at risk are better spared, the delivery time is shortened and the number of delivered UM is decreased. (C) 2010 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:679 / 689
页数:11
相关论文
共 72 条
[1]   Comparison of IMRT planning with two-step and one-step optimization: a strategy for improving therapeutic gain and reducing the integral dose [J].
Abate, A. ;
Pressello, M. C. ;
Benassi, M. ;
Strigari, L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (23) :7183-7198
[2]  
Alaei Parham, 2004, Med Dosim, V29, P1, DOI 10.1016/j.meddos.2003.10.002
[3]   Conformal intensity modulated radiation therapy for localized prostate cancer: Toward a new standard [J].
Azria, D. ;
Ailleres, N. ;
Moscardo, C. Llacer ;
Hay, M. -H. ;
Dubois, J. -B. ;
Fenoglietto, P. .
CANCER RADIOTHERAPIE, 2009, 13 (05) :409-415
[4]   A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy [J].
Baltas, D ;
Kolotas, C ;
Geramani, K ;
Mould, RF ;
Ioannidis, G ;
Kekchidi, M ;
Zamboglou, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (02) :515-524
[5]   The getug 70 GY vs. 80 GY randomized trial for localized prostate cancer:: Feasibility and acute toxicity [J].
Beckendorf, V ;
Guérif, S ;
Le Prisé, E ;
Cosset, JM ;
Lefloch, O ;
Chauvet, B ;
Salem, N ;
Chapet, O ;
Bourdin, S ;
Bachaud, JM ;
Maingon, P ;
Lagrange, JL ;
Malissard, L ;
Simon, JM ;
Pommier, P ;
Hay, MH ;
Dubray, B ;
Luporsi, E ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1056-1065
[6]   Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study [J].
Bedford, James L. ;
Hansen, Vibeke Nordmark ;
Mcnair, Helen A. ;
Aitken, Alexandra H. ;
Brock, Juliet E. C. ;
Warrington, Alan P. ;
Brada, Michael .
ACTA ONCOLOGICA, 2008, 47 (07) :1438-1443
[7]   Evaluation of the Delta4 phantom for IMRT and VMAT verification [J].
Bedford, James L. ;
Lee, Young K. ;
Wai, Philip ;
South, Christopher P. ;
Warrington, Alan P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :N167-N176
[8]   COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) [J].
Bedford, James L. ;
Warrington, Alan P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :537-545
[9]   The α/β ratio for prostate cancer:: What is it, really? [J].
Bentzen, SM ;
Ritter, MA .
RADIOTHERAPY AND ONCOLOGY, 2005, 76 (01) :1-3
[10]  
Brenner DJ, 2002, INT J RADIAT ONCOL, V52, P6