Radiobiological comparison between Cobalt-60 and Iridium-192 high-dose-rate brachytherapy sources: Part I-cervical cancer

被引:4
作者
Dayyani, Mahdieh [1 ]
Hoseinian-Azghadi, Elie [2 ]
Miri-Hakimabad, Hashem [3 ]
Rafat-Motavalli, Laleh [3 ]
Abdollahi, Sara [4 ]
Mohammadi, Najmeh [5 ]
机构
[1] Reza Radiotherapy & Oncol Ctr, Radiat Oncol Dept, Mashhad, Razavi Khorasan, Iran
[2] Reza Radiotherapy & Oncol Ctr, Res & Educ Dept, Mashhad, Razavi Khorasan, Iran
[3] Ferdowsi Univ Mashhad, Fac Sci, Phys Dept, Mashhad, Razavi Khorasan, Iran
[4] Reza Radiotherapy & Oncol Ctr, Med Phys Dept, Mashhad, Razavi Khorasan, Iran
[5] Sahand Univ Technol, Fac Sci, Phys Dept, Tabriz, Iran
关键词
brachytherapy boost; cervical cancer; high-dose-rate brachytherapy; radiobiology; SOCIETY CONSENSUS GUIDELINES; LOCALLY ADVANCED-CARCINOMA; AMERICAN BRACHYTHERAPY; RETROSPECTIVE ANALYSIS; DOSIMETRIC DIFFERENCES; UTERINE CERVIX; WORKING GROUP; RECOMMENDATIONS; COMPLICATIONS; RADIOTHERAPY;
D O I
10.1002/mp.15177
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study aimed to compare the biological effective doses (BEDs) to clinical target volume (CTV) and organs at risk (OARs) for cervical cancer patients treated with high-dose-rate (HDR) Iridium-192 (Ir-192) or Cobalt-60 (Co-60) brachytherapy (BT) boost and to determine if the radiobiological differences between the two isotopes are clinically relevant. Methods Considering all radiosensitivity parameters and their reported variations, the BEDs to CTV and OARs during HDR Co-60/Ir-192 BT boost were evaluated at the voxel level. The anatomical differences between individuals were also taken into account by retrospectively considering 25 cervical cancer patients. The intrafraction repair, proliferation, hypoxia-induced radiosensitivity heterogeneity, relative biological effectiveness (RBE), and source aging dose-rate variation were also taken into account. The comparisons in CTV were performed based on equivalent uniform BED (EUBED). Results Considering nominal parameters with no RBE correction, the CTV EUBEDs were almost similar with a median ratio of similar to 1.00 (p < 0.00001), whereas RBE correction resulted in 3.9%-5.5% (p = 0.005, median = 4.8%) decrease for Co-60 with respect to Ir-192. For OARs, the median values of D-2cc (in EQD2(3)) for Co-60 were lower than that of Ir-192 up to 9.2% and 11.3% (p < 0.00001) for nominal parameters and fast repair conditions, respectively. In addition, for a nominal value (reported range) of radiosensitive parameters, the CTV EUBED differences of up to 6% (5%-10%) were assessed for HDR-BT component. Conclusion The RBE values are the most important cause of discrepancies between the two sources. By comparing BED/EUBEDs to CTV and OARs between Co-60 and Ir-192 sources, this numerical study suggests that a dose escalation to similar to 4% is feasible and safe while sparing well the surrounding normal tissues. This 4% dose escalation should be benchmarked with clinical evidences (such as the results of clinical trials) before it can be used in clinical practice.
引用
收藏
页码:6213 / 6225
页数:13
相关论文
共 48 条
[1]   A revised dosimetric characterization of 60Co BEBIG source: From single-source data to clinical dose distribution [J].
Abdollahi, Sara ;
Dayyani, Mahdieh ;
Hoseinian-Azghadi, Elie ;
Miri-Hakimabad, Hashem ;
Rafat-Motavalli, Laleh .
BRACHYTHERAPY, 2018, 17 (06) :1011-1022
[2]   Dosimetry of HDR afterloading machines with Ir-192-und Co-60-sources: Comparison of different international protocols [J].
Abu Zakaria, Golam ;
Schuette, Wilhelm ;
Azhari, Hasin Anupama .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (03) :215-224
[3]   Cervical Cancer, Version 1.2020 Featured Updates to the NCCN Guidelines [J].
Abu-Rustum, Nadeem R. ;
Yashar, Catheryn M. ;
Bean, Sarah ;
Bradley, Kristin ;
Campos, Susana M. ;
Chon, Hye Sook ;
Chu, Christina ;
Cohn, David ;
Crispens, Marta Ann ;
Damast, Shari ;
Fisher, Christine M. ;
Frederick, Peter ;
Gaffney, David K. ;
Giuntoli, Robert, II ;
Han, Ernest ;
Huh, Warner K. ;
Lurain, John R., III ;
Mariani, Andrea ;
Mutch, David ;
Nagel, Christa ;
Nekhlyudov, Larissa ;
Fader, Amanda Nickles ;
Remmenga, Steven W. ;
Reynolds, R. Kevin ;
Sisodia, Rachel ;
Tillmanns, Todd ;
Ueda, Stefanie ;
Urban, Renata ;
Wyse, Emily ;
McMillian, Nicole R. ;
Motter, Angela D. .
JOURNAL OF THE NATIONAL COMPREHENSIVE CANCER NETWORK, 2020, 18 (06) :661-666
[4]   Compendium of fractionation choices for gynecologic HDR brachytherapy-An American Brachytherapy Society Task Group Report [J].
Albuquerque, Kevin ;
Hrycushko, Brian A. ;
Harkenrider, Matthew M. ;
Mayadev, Jyoti ;
Klopp, Ann ;
Beriwal, Sushil ;
Petereit, Daniel G. ;
Scanderbeg, Daniel J. ;
Yashar, Catherine .
BRACHYTHERAPY, 2019, 18 (04) :429-436
[5]  
Andrassy M., 2012, Fis Med, V13, P125
[6]  
[Anonymous], 2016, BRACHYTHERAPY, DOI DOI 10.1016/J.BRACHY.2016.04.071
[7]   Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma [J].
Candela-Juan, Cristian ;
Perez-Calatayud, Jose ;
Ballester, Facundo ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2013, 40 (03)
[8]   The incorporation of the concept of minimum RBE (RBEmin) into the linear-quadratic model and the potential for improved radiobiological analysis of high-LET treatments [J].
Carabe-Fernandez, Alejandro ;
Dale, Roger G. ;
Jones, Bleddyn .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2007, 83 (01) :27-39
[9]   Effects of oxygen on intrinsic radiation sensitivity: A test of the relationship between aerobic and hypoxic linear-quadratic (LQ) model parameters [J].
Carlson, David J. ;
Stewart, Robert D. ;
Semenenko, Vladimir A. .
MEDICAL PHYSICS, 2006, 33 (09) :3105-3115
[10]   Brachytherapy: An overview for clinicians [J].
Chargari, Cyrus ;
Deutsch, Eric ;
Blanchard, Pierre ;
Gouy, Sebastien ;
Martelli, Helene ;
Guerin, Florent ;
Dumas, Isabelle ;
Bossi, Alberto ;
Morice, Philippe ;
Viswanathan, Akila N. ;
Haie-Meder, Christine .
CA-A CANCER JOURNAL FOR CLINICIANS, 2019, 69 (05) :386-401