Monitoring of phenytoin in human breast milk, maternal plasma and cord blood plasma by solid-phase extraction and liquid chromatography

被引:21
作者
Shimoyama, R
Ohkubo, T [1 ]
Sugawara, K
Ogasawara, T
Ozaki, T
Kagiya, A
Saito, Y
机构
[1] Hirosaki Univ Hosp, Dept Pharm, Hirosaki, Aomori, Japan
[2] Hirosaki Univ, Sch Med, Dept Obstet & Gynecol, Hirosaki, Aomori 036, Japan
关键词
phenytoin; human breast milk; plasma; solid-phase extraction; HPLC;
D O I
10.1016/S0731-7085(97)00277-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid liquid chromatographic method for the quantitation of phenytoin in human breast milk, maternal plasma and cord blood plasma was developed using a Develosil(R) C-8 5 mu m reversed phase column and a potassium dihydrogen phosphate buffer/acetonitrile mobile phase. Phenytoin and mephenytoin as an internal standard were detected by ultraviolet absorbance at 240 mm. The sample preparation method involves a rapid and simple procedure based on solid-phase extraction using a C-18-bonded phase. Phenytoin could be determined in the concentration range of 0.05-3 mu g ml(-1). The recovery of phenytoin added to human breast milk and plasma were 91.6-94.7 and 91.6-96.0%, respectively, with coefficient of variation less than 4.2 and 8.7%. The method has been used for drug level monitoring in the human breast milk, maternal plasma and cord blood plasma samples that were taken from patients treated with phenytoin. The average ratio between the breast milk concentration versus the plasma concentration was 0.28 +/- 0.1, with a rather poor correlation (r = 0.3033). (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:863 / 869
页数:7
相关论文
共 23 条
[1]  
ANDERSEN AT, 1993, J CHROMATOGR, V621, P189
[2]  
FINCH E, 1954, J OBSTET GYN BRIT EM, V61, P833
[3]   FACTORS AFFECTING THE MILK-TO-PLASMA DRUG CONCENTRATION RATIO IN LACTATING WOMEN - PHYSICAL INTERACTIONS WITH PROTEIN AND FAT [J].
FLEISHAKER, JC ;
DESAI, N ;
MCNAMARA, PJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (03) :189-193
[4]   IMPROVED LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHENYTOIN AND SALICYLATE USING RADIAL COMPRESSION SEPARATION [J].
GREENBLATT, DJ ;
MATLIS, R ;
ABERNETHY, DR ;
OCHS, HR .
JOURNAL OF CHROMATOGRAPHY, 1983, 275 (02) :450-457
[5]   RELATION OF DOSAGE AND TIME OF ADMINISTRATION OF DIPHENYLHYDANTOIN TO ITS TERATOGENIC EFFECT IN MICE [J].
HARBISON, RD ;
BECKER, BA .
TERATOLOGY, 1969, 2 (04) :305-&
[6]   AUTOMATED-ANALYSIS OF FREE AND TOTAL CONCENTRATIONS OF 3 ANTIEPILEPTIC DRUGS IN PLASMA WITH ONLINE DIALYSIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JOHANSEN, K ;
KROGH, M ;
ANDRESEN, AT ;
CHRISTOPHERSEN, AS ;
LEHNE, G ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 669 (02) :281-288
[7]   SIMPLIFIED QUANTITATIVE-DETERMINATION OF PLASMA PHENYTOIN - ONLINE PRECOLUMN HIGH-PERFORMANCE LIQUID IMMUNOAFFINITY CHROMATOGRAPHY WITH SAMPLE PRE-PURIFICATION [J].
JOHANSSON, B .
JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01) :107-113
[8]   SYNTHESIS OF POLYMER-COATED MIXED-FUNCTIONAL PACKING MATERIALS FOR DIRECT ANALYSIS OF DRUG-CONTAINING SERUM AND PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KANDA, T ;
KUTSUNA, H ;
OHTSU, Y ;
YAMAGUCHI, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 672 (1-2) :51-57
[9]   LEVELS OF ANTICONVULSANTS IN BREAST-MILK [J].
KANEKO, S ;
SATO, T ;
SUZUKI, K .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1979, 7 (06) :624-626
[10]   CONCURRENT DETERMINATION OF VALPROIC ACID WITH OTHER ANTIEPILEPTIC DRUGS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KUSHIDA, K ;
ISHIZAKI, T .
JOURNAL OF CHROMATOGRAPHY, 1985, 338 (01) :131-139