Effects of Varying Matching Between Collimator Hole and Scintillator Pixel on Gamma Camera Image Resolution

被引:1
作者
Kim, Minho [1 ,2 ]
Bae, Jae Keon [1 ]
Kim, Kyeong Min [1 ]
Lee, Wonho [3 ]
机构
[1] Korea Inst Radiol & Med Sci, Div Med Radiat Equipment, Seoul 01812, South Korea
[2] Korea Univ, Dept Bioconvergence Engn, Seoul 02841, South Korea
[3] Korea Univ, Sch Hlth & Environm Sci, Seoul 02841, South Korea
关键词
Gamma camera; Pixelated scintillator; Parallel hole collimator; Monte Carlo simulation; Spatial resolution; MYOCARDIAL-PERFUSION; HIGH-SENSITIVITY; SPECT; SYSTEM; DESIGN; VALIDATION; DETECTORS; COMPACT;
D O I
10.3938/jkps.72.455
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A collimator is a key component of gamma cameras, which affects imaging performance significantly. Recently, pixelated scintillator arrays are widely applied in the development of highresolution gamma cameras, instead of monolithic scintillator blocks. Therefore, combining the collimator and the pixelated scintillator has been a crucial factor in achieving good imaging performance. In this study, we investigated the effects of the shape and position of a collimator hole on the image resolution of a gamma camera with a pixelated scintillator. We designed a pixel-matched collimator and a low-energy high-resolution (LEHR) collimator with hexagonal shaped holes that have the same collimator geometrical efficiency. Simulation experiments were performed with a Monte Carlo simulation package (GATE v7.0). For both types of collimator, camera sensitivity was measured for validating the collimator efficiency, and planar images were obtained to measure spatial resolution, with changing the line profile angle based on the septa direction. Camera sensitivities for both collimators were equivalent (difference = 1.76 +/- 0.51%). In contrast to the case of the pixel-matched collimator, in the case of the LEHR collimator, as the angle of the line profile varied, the spatial resolution showed a difference at each profile angle. In the case when two collimator holes symmetrically matched with one scintillator pixel, the spatial resolution showed a 64.87% difference in its maximum and a position distortion of 26.06% from the original source position, according to the profile angle, compared to the other unmatched cases. These results showed that using a pixel-matched collimator in gamma camera systems employing a pixelated scintillator is essential for the exact delineation of small regions using high resolution gamma camera imaging.
引用
收藏
页码:455 / 461
页数:7
相关论文
共 25 条
  • [1] Optimization of Parallel-Hole Collimators for Intraoperative Localization of Iodine-125 Seeds
    Arsenali, Bruno
    Gilhuijs, Kenneth G. A.
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2527 - 2532
  • [2] 131I activity quantification of gamma camera planar images
    Barquero, Raquel
    Garcia, Hugo P.
    Incio, Monica G.
    Minguez, Pablo
    Cardenas, Alexander
    Martinez, Daniel
    Lassmann, Michael
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03) : 909 - 926
  • [3] A Parallel-Cone Collimator for High-Energy SPECT
    Beijst, Casper
    Elschot, Mattijs
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 476 - 482
  • [4] A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential
    Bocher, Moshe
    Blevis, Ira M.
    Tsukerman, Leonid
    Shrem, Yigal
    Kovalski, Gil
    Volokh, Lana
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) : 1887 - 1902
  • [5] Evaluation of a compact, high-resolution SPECT detector based on digital silicon photomultipliers
    Bouckaert, Carmen
    Vandenberghe, Stefaan
    Van Holen, Roel
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7521 - 7539
  • [6] Characterisation of a high resolution small field of view portable gamma camera
    Bugby, S. L.
    Lees, J. E.
    Bhatia, B. S.
    Perkins, A. C.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 331 - 339
  • [7] Cherry S. R., 2012, PHYS NUCL MED, P223
  • [8] Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology
    Erlandsson, Kjell
    Kacperski, Krzysztof
    van Gramberg, Dean
    Hutton, Brian F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) : 2635 - 2649
  • [9] A Molecular Approach to Breast Imaging
    Fowler, Amy M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) : 177 - 180
  • [10] Cardiac Dedicated Ultrafast SPECT Cameras: New Designs and Clinical Implications
    Garcia, Ernest V.
    Faber, Tracy L.
    Esteves, Fabio P.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (02) : 210 - 217