Experimental investigation on temperature oscillation in a miniature loop heat pipe with flat evaporator

被引:53
作者
Zhang, Xianfeng [1 ,2 ]
Huo, Jiepeng [1 ]
Wang, Shuangfeng [1 ]
机构
[1] S China Univ Technol, Key Lab Enhanced Heat Transfer & Energy Conservat, Minist Educ, Guangzhou 510640, Guangdong, Peoples R China
[2] CETC 38 Res Inst, Hefei 230088, Peoples R China
关键词
Miniature loop heat pipe; Flat evaporator; Temperature oscillation; Working fluid; Phase distribution; OPERATIONAL CHARACTERISTICS;
D O I
10.1016/j.expthermflusci.2011.09.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, a series of experiments were conducted to investigate the effect of temperature oscillation on startup behavior and operating performance in a miniature LHP with flat evaporator of 8 mm thick. The evaporator with sintered copper powder wick is in series structure with compensation chamber and made of copper. Water is the working fluid. It is found that the LHP is able to start up at heat load of 15 W with temperature oscillation. And the oscillating frequency of temperature rises and amplitude decreases with increasing heat load. For the LHP in the present work, temperature oscillation is caused by insufficient driving force and phase distribution of working fluid in the compensation chamber under different heat load. The development of unstable operation in the LHP is the reflection of the re-distribution of working fluid in the loop while the hydrodynamic and thermal equilibrium of the loop is broken and re-built repeatedly. For specific heat load, high operating temperature can improve the operating stability of LHP due to large capillary force. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 25 条
[1]   Steady state operation of a copper-water LHP with a flat-oval evaporator [J].
Becker, S. ;
Vershinin, S. ;
Sartre, V. ;
Laurien, E. ;
Bonjour, J. ;
Maydanik, Yu. F. .
APPLIED THERMAL ENGINEERING, 2011, 31 (05) :686-695
[2]  
Chen P.H., 2008, RECENT PATENTS ENG, V2, P74
[3]   Operating temperature and distribution. of a working fluid in LHP [J].
Chernysheva, M. A. ;
Vershinin, S. V. ;
Maydanik, Yu. F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (13-14) :2704-2713
[4]  
Gai D.X., 2009, THESIS HUAZHONG U SC
[5]  
Goncharov K.A., 1994, 941577 SEA
[6]   Thermal operational characteristics of a small-loop heat pipe [J].
Kaya, T ;
Ku, JT .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2003, 17 (04) :464-470
[7]  
Kaya T., 990477 AIAA
[8]  
Ku J., 1999, 29 INT C ENV SYST DE
[9]  
Launay S., 2011, FRONTIERS HEAT PIPES, V2, P1
[10]   Parametric analysis of loop heat pipe operation: a literature review [J].
Launay, Stephane ;
Sartre, Valerie ;
Bonjour, Jocelyn .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (07) :621-636