Impact of Sampling Rate on Wearable-Based Fall Detection Systems Based on Machine Learning Models

被引:50
作者
Liu, Kai-Chun [1 ]
Hsieh, Chia-Yeh [1 ]
Hsu, Steen Jun-Ping [2 ]
Chan, Chia-Tai [1 ]
机构
[1] Natl Yang Ming Univ, Dept Biomed Engn, Taipei 11221, Taiwan
[2] Minghsin Univ Sci & Technol, Dept Informat Management, Hsinchu 30401, Taiwan
关键词
Fall detection systems; sampling rates; machine learning models; wearable sensors; CLASSIFICATION; ALGORITHMS;
D O I
10.1109/JSEN.2018.2872835
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Falls are a leading health risk for the elderly. Various wearable-based fall detection systems based on machine learning models have been developed to provide emergency alarms and services to improve safety and health-related quality of life. To support long-term healthcare services, the appropriate sampling rate, which plays a vital role in a fall detection system, must be investigated to guarantee the performance accuracy and energy efficiency. Intuitively, decreasing the sampling rate of sensor nodes can provide computing and energy savings. However, there is a lack of research exploring the performance accuracy of fall detection systems in terms of sampling rate, especially for machine learning models. In this paper, the effects of decreasing sampling rates (ranging from 200/128 to 3 Hz) on wearable-based fall detection systems are investigated based on four machine learning models: support vector machine (SVM), k-nearest neighbor, Naive Hayes, and decision tree. Two emulated fall data sets, the SisFall public data set and the proposed data set of this paper, are used to allow an objective investigation of sampling rates. The findings show that fall detection systems based on SVM modeling and a radial basis function could achieve at least 98% and 97% accuracy, with sampling rates of 11.6 and 5.8 Hz, respectively. Overall, the experimental results demonstrate that a sampling rate of 22 Hz is sufficient for most machine learning models to support wearable-based fall detection systems (accuracy >= 97%).
引用
收藏
页码:9882 / 9890
页数:9
相关论文
共 41 条
[1]  
[Anonymous], IEEE J BIOMED HLTH I
[2]  
[Anonymous], 2015 IEEE INT C COMP
[3]  
[Anonymous], IEEE T IND INFORM
[4]  
[Anonymous], 2016, SENSORS
[5]  
[Anonymous], J AMBIENT INTELL HUM
[6]   A Biomechanical Analysis of Ventral Furrow Formation in the Drosophila Melanogaster Embryo [J].
Conte, Vito ;
Ulrich, Florian ;
Baum, Buzz ;
Munoz, Jose ;
Veldhuis, Jim ;
Brodland, Wayne ;
Miodownik, Mark .
PLOS ONE, 2012, 7 (04)
[7]   A Survey on Activity Detection and Classification Using Wearable Sensors [J].
Cornacchia, Maria ;
Ozcan, Koray ;
Zheng, Yu ;
Velipasalar, Senem .
IEEE SENSORS JOURNAL, 2017, 17 (02) :386-403
[8]   A Movement Decomposition and Machine Learning-Based Fall Detection System Using Wrist Wearable Device [J].
de Quadros, Thiago ;
Lazzaretti, Andre Eugenio ;
Schneider, Fabio Kurt .
IEEE SENSORS JOURNAL, 2018, 18 (12) :5082-5089
[9]   Detection and Classification of Postural Transitions in Real-World Conditions [J].
Ganea, Raluca ;
Paraschiv-Ionescu, Anisoara ;
Aminian, Kamiar .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2012, 20 (05) :688-696
[10]   Quantitative Falls Risk Assessment Using the Timed Up and Go Test [J].
Greene, Barry. R. ;
O'Donovan, Alan ;
Romero-Ortuno, Roman ;
Cogan, Lisa ;
Scanaill, Cliodhna Ni ;
Kenny, Rose A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (12) :2918-2926