Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system

被引:89
|
作者
Kitagawa, T
Tanimoto, Y
Odaki, M
Nemoto, K
Aida, M
机构
[1] Nihon Univ, Sch Dent, Dept Dent Biomat, Matsudo, Chiba 2718587, Japan
[2] Nihon Univ, Sch Dent, Dept Crown Bridge Prosthodont, Matsudo, Chiba 2718587, Japan
关键词
computer modeling/simulation; finite element analysis; implant design; rotation; nonlinear dynamic analysis;
D O I
10.1002/jbm.b.30328
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to investigate the influence of implam/abutment joint designs on abutment screw loosening in a dental implant system, using nonlinear dynamic analysis of the finite element method (FEM). This finite element simulation study used two dental implant systems: the Ankylos implant system (Degusa Dental, Hanau, German) with a taper joint (taper joint-type model), and the Branemark implant system (Nobel Biocare, Gothenburg, Sweden) with an external hex joint (external hex joint-type model). The nonlinear dynamic analysis was performed using three-dimensional finite element analysis. In comparing the movement of the taper type-joint model and external hex type-joint model, it was found that the external hex type-joint model had greater movement than the taper type-joint model. The external hex joint-type model showed rotation movement, whereas the movement of the taper joint-type model showed no rotation. It was concluded that the nonlinear dynamic analysis used in this study clearly demonstrated the differences in rotation of components in dental implant systems with taper or external hex joints. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:457 / 463
页数:7
相关论文
共 50 条
  • [31] Stress Analysis in Anterior Single Unit Implant with Different Abutment Connection Designs: A Finite Element Study
    Kumma, Pattamapom
    Sareekuea, Patcharee
    Iadnagkhan, Panupong
    Puengpaiboon, Usanee
    Rattanapan, Nichapat
    Kunarak, Piriya
    Sukjamsri, Chamaipom
    2023 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND APPLICATIONS, ICBEA, 2023, : 93 - 97
  • [32] Load Distribution in Tooth and Implant-Abutment Identical Cases
    Ulusoy, Muhammed Mutahhar
    Arinc, Hakan
    Ozden, Asiye Nehir
    CYPRUS JOURNAL OF MEDICAL SCIENCES, 2020, 5 (03): : 211 - 216
  • [33] STATIC AND FATIGUE RESISTANCE OF TWO TYPES OF IMPLANT/ABUTMENT CONNECTORS
    Fanali, S.
    Villa, T.
    Lico, S.
    Celletti, R.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (02) : 523 - 528
  • [34] Biomechanical effect of abutment on stability of orthodontic mini-implant
    Motoyoshi, M
    Yano, S
    Tsuruoka, T
    Shimizu, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 480 - 485
  • [35] Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: A finite element analysis
    Huang, Ling-Shiuan
    Huang, Yen-Chang
    Yuan, Cadmus
    Ding, Shinn-Jyh
    Yan, Min
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (01) : 248 - 263
  • [36] Influences of Internal Tapered Abutment Designs on Bone Stresses Around a Dental Implant: Three-Dimensional Finite Element Method With Statistical Evaluation
    Chu, Chun-Ming
    Huang, Heng-Li
    Hsu, Jui-Ting
    Fuh, Lih-Jyh
    JOURNAL OF PERIODONTOLOGY, 2012, 83 (01) : 111 - 118
  • [37] An investigation of effect of rigid and nonrigid connector designs on implant as pier abutment in implant tooth-supported fixed dental prosthesis with three-dimensional finite element analysis: An In vitro study
    Kumar, S. Manoj
    Jei, J. Brintha
    Krishnan, Murugesan
    ADVANCES IN HUMAN BIOLOGY, 2021, 11 (04) : 45 - 50
  • [38] Minimum Abutment Height to Eliminate Bone Loss: Influence of Implant Neck Design and Platform Switching
    Spinato, Sergio
    Galindo-Moreno, Pablo
    Bernardello, Fabio
    Zaffe, Davide
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 405 - 411
  • [39] Influence of Abutment Material on the Stress of Implant-supported All-ceramic Single Crown
    Gao Shaohuai
    Duan Haiying
    Li Zhiyong
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2012, 27 (01): : 96 - 99
  • [40] Influence of abutment material on the stress of implant-supported all-ceramic single crown
    Shaohuai Gao
    Haiying Duan
    Zhiyong Li
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2012, 27 : 96 - 99